Product Literature

Removing the arm assembly
Insert screw driver behind notch in locking cam and pry
outward
Remove arm assembly as shown
AVENTOS HS Assembly
AVENTOS
Attaching the arm assembly
Find the right and left arm assemblies and match them to the correct
side of the cabinet.
Attach the arm assembly to the lift mechanism as shown
Lift up on the arm assembly to lock into place
1
2
Attaching the doors
Attach the door using the CLIP mechanism to the arm assembly
Attaching the stabilizer rod
Cut the stabilizer rod to fit the cabinet. Length = interior cabinet width minus 129 (5-1/16')
After cutting the rod to size follow steps 1, 2, and 3 below.
1 2 3
1 2
Slide the stabilizer arm cover caps onto the rod
Attach the stabilizer rod to spring loaded arm assembly
Slide stabilizer arm cover caps over rod on each end
1
2
3
Warning: Risk of injury by arm assembly!
1
2
1 2
Do not push telescopic arm down
Remove telescopic arm from mechanism before installing cabinet
© 2021 Blum, Inc. Subject to technical modifications without notice
30