Locating pin locations
Panel
TR = Top reveal
TDH = Top ddor height
Top door height
(TDH)
Y
231 to 271
TDH
x
.6
-
28
+
TR
272 to 531
TDH
x
.6
-
57
+
TR
Use the Universal individual template to pre-bore the 5 mm locating pin holes for the AVENTOS HF
lift mechanism.
Face frame
Top door height
(TDH)
Y
231 to 271
TDH
x
.6
-
28
+
TR
272 to 531
TDH
x
.6
-
57
+
TR
TR = Top reveal
TDH = Top door height
TR
Y
192 37
Top door height
Ø5
NOTE: Face frame
cabinets must be blocked
out flush with the frame
Assembly
Universal individual template is available for pre-boring locating pins
Part no.
65.1051.02
WARNING
Risk of injury from spring-loaded arm
Do not push arm assembly down or leave in the down position
Remove mechanism before installing or removing cabinet
192
Y
37
Top door height
TR
Ø5