Use and Care Manual

14
BLUETTI
7.2.1. AC Output Voltage & Frequency
NOTE: Please check the output voltage, frequency, and other parameters
BEFORE using EP500Pro for the first time. The EP500Pro 100-120V AC version
cannot be set to 220-240V AC output.
The Output frequency and voltage can only be tweaked when the AC is OFF(tap
the AC icon at homepage to turn off AC output if it`s ON).
The list of standard output voltage and frequency in 5 regions or countries. You
may tap on the screen to set the parameters as needed.
JP Output: 100V/50Hz or 60Hz
US Output: 120V/60Hz
AU Output:240V/50Hz
EU/UK Output: 230V/50Hz
7.2.2 DC Input Source
DC Input Source: EP500Pro integrates dual MPPT and separates the DC input
source into DC1 and DC2 in parallel. DC1 indicates the first group of DC input
source as the labels written on MC4 plug of PV charging cables:
DC1 PV+ and DC1 PV-, DC2 PV+ and DC2 PV-. DC1/DC2 consist of both positive
pole and negative pole of the MC4 plugs.
Both DC1 and DC2 input source can be set on touchscreen: (Homepage - Settings
- DC1/DC2 Input Source).
DC1 PV+/PV-
DC2 PV+/PV-
Can be set on screen:
(Homepage - Settings - DC1/DC2 Input Source)