Pin
number
Name Description
1 GND Ground
2 POS Power supply input 8 to 30 Vdc
3 IGN Ignition sense input – turns ON/OFF the modem
4 O3 Digital Output 3
O3 IGN
GND POS
Power input to the modem is protected against reverse polarity and over-
voltage.
The POS input is also monitored by the modem as a dedicated analog input.
The IGN input is also monitored by the modem as a dedicated digital input.
Current consumption
Active mode:
Æ the modem is in a call and is transmitting or receiving data
Average of 169mA @ PCS 1900Mhz (Peak: 286 mA)
Average of 154mA @ Cellular 800Mhz (Peak: 268 mA)
Idle mode:
Æ the modem is either not in a call, or is in one but is Dormant
Æ Dormant is the state the modem is in after 20sec of inactivity
49mA
Ignition OFF:
Æ the modem is turned OFF but still has power from its POS input
Æ all circuitry is shutdowns except for Non-Volatile memory and Real Time Clock
1mA
Revision 1.0 Copyright © 2004-2006 BlueTree Wireless Data Inc. Page 13 of 44