Owners manual
MWS- 808D
8
WIRE TYPE GUIDE
Ø Sheathed flat cable: ≤ 0.55” (14mm) x 0.31” (8mm) WxH
Ø Twisted flat cable: ≤ 0.31” (8mm) x 0.23” (6mm) WxH
Ø Single-core cable: Dia. Φ0.07” (2mm) ~ Φ1” (25mm)
Round cable Sheathed flat cable Twisted flat cable Single-core cable
WIRE GUIDE DIAGRAM
RUNNING WIRE
Ø Do all pre-operational and operational safety checks from Chapter 1.
Ø Securing the machine and installing the hand-wheel and hand-crank or using a user
supplied chuck type drill to the 12mm drill shaft.
Ø Have your wires ready to process, by separating them by type and cutting them into
3-4’ lengths.
Ø Select a wire to strip.
Ø Decide on which guide is the correct guide input.
Ø If using the hand crank- run the wire through while turning the hand-crank until the
wire is all the way through. You can also partially run the wire through with the hand-
crank and go to the output of the machine and pull the wire through the remainder of
the way.