Data Sheet

10/10/2018 Fathom Spool Documentation
http://docs.bluerobotics.com/spool/#specifications 18/19
Inspect and clean the contacts of the Binder 770 connectors if necessary.
Every 100 Hours of Operation or Every 6 Months
Check the operation and condition of the sealing x-ring in the slip ring core. If there is signicant resistance or
rough running, inspect with the following steps:
1. Loosen the connector on the outside of the unit to break the seal and open an air vent.
2. Remove the four #4-5/8” self tapping screws around the perimeter of the blue slip ring cap ange.
3. The slip ring cap can now be pulled straight away from the unit, and the x-ring can be inspected for
wear. If there is excessive wear it should be replaced. Re-grease if necessary.
4. Reverse the steps for reassembly, making sure to fully tuck the slip ring wires into the cap before
replacing it to avoid pinching or cutting any wires.