Data Sheet

MS5837-30BA
Ultra Small Gel Filled Pressure Sensor
SENSOR SOLUTIONS /// MS5837-30BA
10/11/2015
2
PERFORMANCE SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Symbol
Conditions
Min.
Typ.
Max
Unit
V
DD
-0.3
+4
V
T
S
-40
+85
°C
P
max
ISO 22810
50
Bar
T
max
40 sec max
250
°C
Human Body
Model
-2
+2
kV
JEDEC standard
No 78
-100
+100
mA
ELECTRICAL CHARACTERISTICS
Symbol
Conditions
Min.
Typ.
Max
Unit
V
DD
1.5
3.0
3.6
V
T
-20
+25
+85
°C
I
DD
OSR
8192
4096
2048
1024
512
256
20.09
10.05
5.02
2.51
1.26
0.63
µA
during conversion
1.25
mA
at 25°C
0.01
0.1
µA
From VDD to GND
100
470
nF
ANALOG DIGITAL CONVERTER (ADC)
Symbol
Conditions
Min.
Typ.
Max
Unit
24
Bit
t
c
OSR 8192
4096
2048
1024
512
256
14.8
7.40
3.72
1.88
0.95
0.48
16.44
8.22
4.13
2.08
1.06
0.54
18.08
9.04
4.54
2.28
1.17
0.60
ms
(1): Maximum values must be applied to determine w aiting times in I2C communication