Datasheet

MS5837-02BA
Gel-filled, ultra-compact, water resistant digital pressure and temperature sensor
TE CONNECTIVITY SENSORS /// MS5837-02BA REV A8 12/2019
Page 3
PERFORMANCE SPECIFICATIONS (Continued)
PRESSURE OUTPUT CHARACTERISTICS (V
DD
= 3 V, T = 25°C UNLESS OTHERWISE NOTED)
Parameter
Conditions
Min.
Typ.
Max
Unit
Operating Pressure Range
300
1200
mbar
Extended Pressure Range
Linear Range of
ADC
10
2000
mbar
Relative Accuracy
(1) (4)
600...1000 mbar, at 20°C
300...1100 mbar, 0...60°C
300...1100 mbar, -20...85°C
-0.5
-2
-4
+0.5
+2
+4
mbar
Resolution RMS
8192
4096
2048
1024
512
256
0.016
0.021
0.028
0.039
0.062
0.11
mbar
Maximum error with supply
voltage
(2)
V
DD
= 1.5 V…3.6 V
±2
mbar
Long-term stability
±2
mbar/yr
Reflow soldering impact
IPC/JEDEC J-STD-020C
(Refer to application note AN808)
±4
mbar
Recovering time after reflow
(3)
7
days
(1)
With autozero at one pressure point
(2)
With autozero at 3V point
(3)
Time to recover at least 66% of reflow impact
(4)
Wet/dry cycle: sensor must be dried typically once a day
TEMPERATURE OUTPUT CHARACTERISTICS (V
DD
= 3 V, T = 25°C UNLESS OTHERWISE NOTED)
Parameter
Conditions
Min.
Typ.
Max
Unit
Relative Accuracy
-20…85°C, 300…1100 mbar
-2
+2
°C
Maximum error with supply
voltage
V
DD
= 1.5 V…3.6 V
±0.3
°C
Resolution RMS
8192
4096
2048
1024
512
256
0.002
0.003
0.004
0.006
0.009
0.012
°C
DIGITAL INPUTS (SDA, SCL)
Parameter
Conditions
Min.
Typ.
Max
Unit
Serial data clock
400
kHz
Input high voltage
80% V
DD
100% V
DD
V
Input low voltage
0% V
DD
20% V
DD
V
Input leakage current
T = 25 °C
0.1
µA
DIGITAL OUTPUTS (SDA)
Parameter
Conditions
Min.
Typ.
Max
Unit
Output high voltage
I
source
= 1 mA
80% V
DD
100% V
DD
V
Output low voltage
I
sink
= 1 mA
0% V
DD
20% V
DD
V