Data Sheet
MS5837-02BA 
Ultra Small Gel Filled Pressure & Temperature Sensor, with Stainless Steel Cap 
TE CONNECTIVITY SENSORS /// MS5837-02BA     09/2017 
Page 9 
I
2
C INTERFACE 
COMMANDS 
The MS5837 has only five basic commands: 
1.  Reset 
2.  Read PROM (112 bit of calibration words) 
3.  D1 conversion 
4.  D2 conversion 
5.  Read ADC result (24 bit pressure / temperature) 
Each I
2
C communication message starts with the start condition and it is ended with the stop condition. The MS5837 
address is 1110110x (write: x=0, read: x=1). 
Size of each command is 1 byte (8 bits) as described in the table below. After ADC read commands, the device will 
return 24 bit result and after the PROM read 16 bit results. The address of the PROM is embedded inside of the 
PROM read command using the a2, a1 and a0 bits. 
Command byte 
hex value 
Bit number 
0 
1 
2 
3 
4 
5 
6 
7 
Bit name 
PRO
M 
CO
NV 
- 
Typ 
Ad2/
Os2 
Ad1/
Os1 
Ad0/
Os0 
Stop 
Command 
Reset 
0 
0 
0 
1 
1 
1 
1 
0 
0x1E 
Convert D1 (OSR=256) 
0 
1 
0 
0 
0 
0 
0 
0 
0x40 
Convert D1 (OSR=512) 
0 
1 
0 
0 
0 
0 
1 
0 
0x42 
Convert D1 (OSR=1024) 
0 
1 
0 
0 
0 
1 
0 
0 
0x44 
Convert D1 (OSR=2048) 
0 
1 
0 
0 
0 
1 
1 
0 
0x46 
Convert D1 (OSR=4096) 
0 
1 
0 
0 
1 
0 
0 
0 
0x48 
Convert D1 (OSR=8192) 
0 
1 
0 
0 
1 
0 
1 
0 
0x4A 
Convert D2 (OSR=256) 
0 
1 
0 
1 
0 
0 
0 
0 
0x50 
Convert D2 (OSR=512) 
0 
1 
0 
1 
0 
0 
1 
0 
0x52 
Convert D2 (OSR=1024) 
0 
1 
0 
1 
0 
1 
0 
0 
0x54 
Convert D2 (OSR=2048) 
0 
1 
0 
1 
0 
1 
1 
0 
0x56 
Convert D2 (OSR=4096) 
0 
1 
0 
1 
1 
0 
0 
0 
0x58 
Convert D2 (OSR=8192) 
0 
1 
0 
1 
1 
0 
1 
0 
0x5A 
ADC Read 
0 
0 
0 
0 
0 
0 
0 
0 
0x00 
PROM Read 
1 
0 
1 
0 
Ad2 
Ad1 
Ad0 
0 
0xA0 to 
0xAE 
Command structure 