Data Sheet
MS5837-02BA 
Ultra Small Gel Filled Pressure & Temperature Sensor, with Stainless Steel Cap 
TE CONNECTIVITY SENSORS /// MS5837-02BA     09/2017 
Page 3 
PERFORMANCE SPECIFICATIONS (Continued) 
PRESSURE OUTPUT CHARACTERISTICS (V
DD
 = 3 V, T = 25°C UNLESS OTHERWISE NOTED) 
Parameter 
Conditions 
Min. 
Typ. 
Max 
Unit 
Operating Pressure Range 
P
range
300 
1200 
mbar 
Extended Pressure Range 
P
ext
Linear Range of 
ADC 
10 
2000 
mbar 
Relative Accuracy 
(1) (4)
600...1000 mbar, at 20°C 
300...1100 mbar, 0...60°C 
300...1100 mbar, -20...85°C 
-0.5 
-2 
-4 
+0.5 
+2 
+4 
mbar 
Resolution RMS 
OSR 
8192 
4096 
2048 
1024 
512 
256 
0.016 
0.021 
0.028 
0.039 
0.062 
0.11 
mbar 
Maximum error with supply 
voltage 
(2)
V
DD 
= 1.5 V…3.6 V 
±2 
mbar 
Long-term stability 
±2 
mbar/yr 
Reflow soldering impact 
IPC/JEDEC J-STD-020C 
(Refer to application note AN808) 
±4 
mbar 
Recovering time after reflow 
(3)
7 
days 
(1)
 With autozero at one pressure point 
(2)
 With autozero at 3V point 
(3)
 Time to recover at least 66% of reflow impact 
(4)
 Wet/dry cycle: sensor must be dried typically once a day 
TEMPERATURE OUTPUT CHARACTERISTICS (V
DD
 = 3 V, T = 25°C UNLESS OTHERWISE NOTED) 
Parameter 
Conditions 
Min. 
Typ. 
Max 
Unit 
Relative Accuracy 
-20…85°C, 300…1100 mbar 
-2 
+2 
°C 
Maximum error with supply 
voltage 
V
DD 
= 1.5 V…3.6 V 
±0.3 
°C 
Resolution RMS 
OSR 
8192 
4096 
2048 
1024 
512 
256 
0.002 
0.003 
0.004 
0.006 
0.009 
0.012 
°C 
DIGITAL INPUTS (SDA, SCL) 
Parameter 
Symbol 
Conditions 
Min. 
Typ. 
Max 
Unit 
Serial data clock 
SCL 
400 
kHz 
Input high voltage 
V
IH
80% V
DD
100% V
DD
V 
Input low voltage 
V
IL
0% V
DD
20% V
DD
V 
Input leakage current 
I
leak
T = 25 °C 
0.1 
µA 
DIGITAL OUTPUTS (SDA) 
Parameter 
Symbol 
Conditions 
Min. 
Typ. 
Max 
Unit 
Output high voltage 
V
OH
I
source
 = 1 mA 
80% V
DD
100% V
DD
V 
Output low voltage 
V
OL
I
sink
 = 1 mA 
0% V
DD
20% V
DD
V 