IM-FAH-Dowflow-0672327-00
Downflow Conversion Kit
used to Modify Air Handler Units for Downflow Application
0672327-00
February 2015
Installation Instructions
2175 West Park Place Blvd., Stone Mountain, GA 30087
www.adpnow.com
Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice
and without obligation on our part. Please contact your ADP representative or distributor to verify details.
© by Advanced Distributor Products. All rights reserved.
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause personal injury,
loss of life, or damage to property.
Installation and service must be performed by a
licensed professional installer (or equivalent) or a
service agency.
CAUTION
Physical contact with metal edges and corners
while applying excessive force or rapid motion can
result in personal injury. Be aware of, and use
caution when working near these areas during
installation or while servicing this equipment.
GENERAL
This kit is used to modify air handler units for use in
downflow applications. The procedure requires that the
installer remove the evaporator coil and re-install it for
downflow air discharge application.
Figure 1 shows the air handler unit as configured at the
factory. As shipped, some models are configured for
upflow air discharge, and some models are configured
for either upflow or horizontal left-hand air discharge.
Figure 2 shows the air handler unit after re-configuring
for installation in downflow air discharge applications.
NOTE: A downflow combustible floor base is not required for the
applicable air handler.
FIGURE 1
As Shipped Configuration
Horizontal
Drain
Connections
(both sides;
not used)
Upflow Drain Pan
Horizontal Drain Pan
(multi-position models only,
to be removed for
downflow application)
Upflow Drain
Connections
FIGURE 2
Insulated Drain
Pan Shields
Installed
Outer Coil Slab Shields
Connection Panel
Air Handler
Access Panel
Downflow Configuration
Downflow Coil
Support Brackets
Installed
Drain Pan
Evaporator Coil in
Downflow Configuration
Go to your app store
and download a free
QR Code Reader
Scan to see
the Downflow
Installation Video