PTAC Service Manual

Service Manual
Installation and Maintenance
69
Secure Unit
1. Tear off shipping tape from the front panel and vent door
and remove the locking screw on vent door.
Note: please remove the tape and screw, otherwise, vent door
can't be used.
2. Remove front panel——pull out from the bottom and then
lift it up.
3. Lift unit level and slide it into the pre-installed wall sleeve.
Note: If GE plastic sleeve is used, the bottom foam seal must
be removed.
4. Unit's supporter should attach closely to wall sleeve. Secure
unit with the supplied screws.
5. Replace front panel——place it from the top on the tab
positions and then push inward at bottom until panel snaps
into place.
caulk caulk
caulk
caulk
wall sleeve
screw
front panel
shipping tape
vent door
GE plastic
sleeve
foam seal
wall sleeve
wall sleeve
supporter