BPHP14 Heat Pump Package Unit Installation Manual
Table Of Contents
Page 12 of 13 507296-01BIssue 1650
3
3
BLK
RED
YEL W/ STRIPE
RED
T2
C
H
F
BLK
GRY
RED
BLK
208V
240V
BLU
YEL
NO
NC
C
BLOWER
CONTROL
NC
C
BLK
C
G
XFMR-R
R
XFMR-C
W1
C
L
R
O
Y1
FAN
HI-PS
24 V
Y
W2
RED
YEL
BLU
WHT
GRN
ORG
RED
BLU
BLU
YEL
BLU
W1 & W2 CAN BE USED TO STAGE
ELECTRIC HEAT ACCESSORY ON
10,15 & 20KW MODELS
5 & 7.5 KW HEATER ACCESSORIES
FUNCTION OFF W1 ONLY.
BLK
DEFROST
CONTROL
WHT
DEFROST
CONTROL
J2-2
J2-4
J2-6
J2-5
WHT
BLK
MOTOR
SPEED TAPS
208/230V-1-60
BLOWER SPEED CHART
UNIT
FACTORY SHIPPED SETTINGS
COOLING INPUT (BLK)
42
48
G
W1
C
R O
THERMOSTAT
L1
T1
COMPRESSOR
CONTACTOR
COMPRESSOR
CONTACTOR
DUAL
CAPACITOR
COMPRESSOR
TRANSFORMER
C
S
R
L2
537660-01
CONNECTION DIAGRAM - HEAT PUMP
(PSC BLOWER) SINGLE PHASE
24V
NOTE:
IF ANY OF THE ORIGINAL
WIRE IS REPLACED THE
SAME SIZE AND TYPE WIRE
MUST BE USED.
USE COPPER CONDUCTOR
ONLY, MIN 75
C WIRE
LINE VOLTAGE FIELD INSTALLED
WARNING-
ELECTRIC SHOCK HAZARD. UNIT
MUST BE GROUNDED IN ACCORDANCE
WITH NATIONAL AND LOCAL CODES.
SEE CHART
FOR WIRING
FUSE
BLOWER
CONTROL
DIAGNOSTIC CODES FOR DEFROST CONTROL LEDS
Note: Because the Pressure Switches are monitored only when "Y1" (Input) is active, the code
for pressure switch open will not be seen when "Y1" is off. Instead, the "Normal Operation" or
"Anti Short Cycle" code will be seen.
Also, when a pressure switch opens and caused a short cycle lockout, the pressure switch-open
code will be seen until it closes, then the short cycle lockout code will flash unless it has already
expired.
(See instructions or markings on System Diagnostic
Module for codes of System Diagnostic Module)
YELLOW W/ STRIPE
BLK
5
4
3
2
1
K1-1
INDOOR
BLOWER
MOTOR
H
M
L
C
2
3
4
1
B3
CAPACITOR
C4
ORG
BLK
FAN
CONDENSER
FAN MOTOR
PUR
J1-2
J1-1
J1-3
B4
K1-2
J2-1
CMC1
C12
J2-3
B1
T1
CONTACTOR
K1
HIGH PRESSURE
SWITCH
THERMAL PROTECTION
SWITCH
(IF USED)
S173
S4
J1-11
J1-12
O-OUT
LO-PS
DF
COMMON
Y1 OUT
REV. VALVE
DEFROST
T'STAT
LOW PRESSURE
SWITCH
GRY
GRY
BLK
BLK
BRN
BRN
BLU
L1
S79
S6
J1-5
J1-6
J1-8
J1-9
J1-7
J1-10
A-15
CMC1
J1: PLUG THROUGH CONTROL PANEL (12 PIN)
J2: PLUG FOR ACCESSORY HEAT (6 PIN)
CONTROL CIRCUIT WIRING TO
24 VOLT, NEC CLASS-2
S1
FLOAT SWITCH
(IF USED)
YEL
YEL
CRANK
CASE
HEATER
(IF USED)
BLK
BLK
HR1
Description
DS2 (GREEN) DS1 (RED)
No Power to Control OFF OFF
Normal Operation / Power to
Control
Simultaneous Slow Flash
Anti-Short Cycle Lockout Alternate Slow Flash
Low Pressure Switch Fault OFF Slow Flash
Low Pressure Switch Lockout OFF ON
High Pressure Switch Fault Slow Flash OFF
High Pressure Switch Lockout ON OFF
Figure 10. Connections Diagram - Heat Pump PSC