BPRPGE14 Manual
507302B01 Page 3 of 6Issue 2122
OPERATING YOUR UNIT
7. Wait 5 minutes to clear out any gas, then smell for gas
(including at the bottom of the unit near the ground). If
you smell gas, stop and follow the directions in WHAT
TO DO IF YOU SMELL GAS on page 1. If you don’t
smell gas, continue to next step.
8. Slide the gas control switch, or turn the gas control knob,
to “ON”.
9. Replace the burner compartment access panel.
10. Turn on all electric power to the unit.
11. Set the thermostat to the desired setting.
12. If the unit will not operate, follow the instructions found
below in To Turn O Gas to Unit and call your service
technician or gas supplier.
Operating Sequence
When the thermostat calls for gas heat, the vent motor will
purge the system for 30 seconds (nominal). When the
prepurge time has expired, the gas valve will open for direct
ignition. When burners are lit, the ame sensor will sense
ame and keep the gas valve open. If the ame sensor
does not sense that a ame has been established, it will
shut o the gas valve. The ignition system is designed
to go through three trials for ignition. If ame still has not
been established after the third trial, the system will go into
lockout. After 1 hour, the system will try three more times.
If the system goes into lockout, it can be reset by turning
your thermostat down or o for 10 seconds and then back
to the desired point.
When the room thermostat is satised, the electrical circuit
to the gas valve is opened and the burners are shut o.
Shutting Down the Unit
To shut down the unit, set the thermostat to the “OFF” position.
To Turn O Gas to Unit
1. Set the thermostat to the lowest setting.
2. Turn o all electric power to the unit if service is to be
performed.
3. Remove the burner compartment access panel.
4. Slide the gas control switch, or turn the gas control knob
“OFF” (see Figure 1). Do not force.
5. Replace the burner compartment access panel.
These units are equipped with an ignition device which
automatically lights the burners. Do not try to light the
burners by hand.
Before operating, smell around furnace area for gas. Be
sure to smell near the unit base because some gas is heavier
than air and will settle to the lowest point. See WHAT TO DO
IF YOU SMELL GAS on page 1 if the odor of gas is present.
Use only your hand to slide the gas control switch; never
use tools. If the switch will not move by hand, don’t try
to repair it. Call a qualied service technician. Force or
attempted repair may result in a re or explosion.
Lighting Instructions
1. STOP! Read the previous safety information.
2. Set the thermostat to the lowest setting.
3. Turn o all electric power to the unit.
4. Remove the burner compartment access panel.
5. This appliance is equipped with an automatic ignition
device. Do not try to light the burners by hand.
6. Slide the gas control switch, or turn the gas control
knob, to “OFF” (see Figure 1).
Figure 1
MANIFOLD
PRESSURE OUTLET
INLET
PRESSURE
PORT
MANIFOLD
PRESSURE
ADJUSTMENT
SCREW