Band the copper lines, wire, and drain hose
Hang the Indoor Air Handler
• Bind the copper lines, the multi-
conductor wire, and drain hose
up with a band as seen in Img 5.
• Take into consideration that
the drain tubing will not run the
entire distance as the copper
lines, so allow the drain tubing
to escape this binding where the
contractor sees fit.
• Feed the bound pipes through the wall sleeve or piping hole.
• Hang the indoor air handler on the wall mounting frame.
• Use sealing gum or expanding foam to ensure there is no air exchange
between the wall sleeve or piping hole and the exterior of the space. This
should be a very tight seal.
• Ensure the indoor air handler is firmly installed on the wall.