Installation & Owners Manual 2017

Blueridge Owners Manual
20
Document Version: 01/2017
Copyright 2017 Alpine Home Air Products
Hex Nut Diameter (in) Tightening Torque (ft-lbs)
1/4 10-13
3/8 25-30
1/2 36-45
5/8 50-60
If the lines are not already insulated, wrap them with insulation and tape
the insulation in place.
5
Wiring the Air Handlers to the outdoor unit
Remove the wire clip on the outdoor unit.
Connect the multi conductor wire that is run from the indoor air handler
to the associating terminals on the outdoor unit. Color coded multi-
conductor is highly recommended to ensure that the wires have been
connected correctly.
Installation of a Single Zone Outdoor Unit
wrench on the union nut (compression fitting). Tighten the union nut ac-
cording to the chart below: