DIY Single Zone Spec Sheet 2020
Blueridge Model
Number
Kit
BM12DIY22 BM18DIY20 BM24DIY20 BM36DIY16
Indoor
Indoor
BM12YDIY22WM BM18YDIY20WM BM24YDIY20WM
BM36YDIY16WM
Outdoor
Outdoor
BM12YDIY22C BM18YDIY20C BM24YDIY20C
BM36YDIY16C
Capacity and Ratings
Cooling
Capacity
(Btu/Hr)
12000
18000
23000 34500
Input (W)
943 1440 1840 4205
Rated current
(A)
8.2 6.26
8
18.3
EER (Btu/w)
12.7 12.5
12.5
8.2
SEER (Btu/w)
22
20 20
16
Heating
Capacity
(Btu/Hr)
12000
18000
25000
36000
Input (W)
1099 1440 2460 3910
Rated current
(A)
8.5 6.26 10.7 17
COP (W/W)
3.2 3.66 2.98
2.7
HSPF4 (Btu/w)
10.0
10 10 8.9
HSPF5 (Btu/w)
8.1
8
8.3 7.5
Operating
Temperature Range
BM12DIY22 BM18DIY20 BM24DIY20
BM36DIY16
Indoor cooling
℃
17
~
32
17
~
32
17
~
32
17
~
32
Indoor heating
℃
0
~
30
0
~
30
0
~
30
0
~
30
Indoor cooling
℉
62.6~89.6
62.6
~89.6
62.6~89.6 62.6~89.6
Indoor heating
℉
32~86 32~86 32~86 32~86
Outdoor cooling
℃
-15~43
-15
~
50
-15
~
50
-15
~
50
Outdoor heating
℃
-25~30 -20~30 -20~30 -20~30
Outdoor cooling
℉
5~109.4 5~122 5~122 5~122
Outdoor heating
℉
-13~86 -4~ 86 -4~86 -4~86
Air Flow and Sound
Levels
BM12DIY22 BM18DIY20 BM24DIY20
BM36DIY16
Indoor air flow
(Hi/Mi/Lo)
m3/h
520/360/250 867/651/544 970/750/570 1400/1000/700
Indoor air flow
(Hi/Mi/Lo)
CFM
305.88/211.76/147.06
510.00/382.94/320.00 570.59/441.18/335.29
823.53/588.24/411.76
Indoor noise level
(Hi/Mi/Lo)
dB(A)
38/31.5/23.5
45/37.5/31 47/42/33.5 52/45/35
Outdoor air flow
m3/h
2000 2500 3800 3800
Outdoor air flow
CFM
1176.47
1470.59
2235.29
2235.29
Outdoor noise level
dB(A)
55 58.5 60