80% TWO STAGE CONSTANT TORQUE 80G2E
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
High Fire Low Fire
AFUE
(ICUS)
Nom.
Cooling
Capacity
(tons)
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Overcurrent
Protection
Nominal
F.L.A.
Trans.
(V.A.)
Motor
Output
(hp)
Approx.
Weight
(lbs.)
Input
(Btuh)
Output
(Btuh)
Input
(Btuh)
Output
(Btuh)
UPFLOW / HORIZONTAL
80G2UH045AE12 44,000 35,000 29,000 23,000 80.0 3 1/2 120-60-1 15 6.1 40 1/2 111
80G2UH070AE12
80G2UH070AE12L
66,000 53,000 43,000 35,000 80.0 3 1/2 120-60-1 15 6.1 40 1/2 121
80G2UH090BE12 88,000 70,000 57,000 46,000 80.0 3 1/2 120-60-1 15 6.1 40 1/2 136
80G2UH090BE16
80G2UH090BE16L
88,000 69,000 57,000 46,000 80.0 4 1/2 120-60-1 15 8.2 40 3/4 140
80G2UH110CE16 110,000 86,000 72,000 58,000 80.0 4 1/2 120-60-1 15 8.2 40 3/4 152
80G2UH110CE20
80G2UH110CE20L
110,000 87,000 72,000 58,000 80.0 5 1/2 120-60-1 15 10.0 40 1 156
DOWNFLOW
80G2DF070AE12 66,000 52,00 43,000 35,000 80.0 3 1/2 120-60-1 15 6.1 40 1/2 123
80G2DF090BE16 88,000 69,000 57,000 46,000 80.0 4 1/2 120-60-1 15 8.2 40 3/4 142
Note: For vent length and clearances to combustibles, please reference installation instructions.
Note: Filters and provisions for mounting are not furnished and must be field provided.
MAJOR REVISION
REVISION CODE
NOM. CFM X 00
12 = 3 TON ADD ON COOLING
16 = 4 TON ADD ON COOLING
20 = 5 TON ADD ON COOLING
BLOWER DRIVE
E = CONSTANT TORQUE ECM
CABINET WIDTH
A = 14.5” WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
AFUE
80 = 80% EFFICENCY
GAS
STAGES
2 = TWO STAGE
CONFIGURATION
UH = UPFLOW/HORIZONTAL
DF = DOWNFLOW
BTUH INPUT
HEATING INPUT X 1000
80 G 2 UH 110 C E 16 -0180 G 2 UH 110 C E 16 -01