BE5V Specifications Sheet

COMPACT AIR HANDLER
BE5V
Page 7
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
“HEAT” Speed
Tap 1 33 45 57 68 78 89 101 115
Tap 2 64 81 96 113 132 145 159 179
Tap 3 133 152 172 190 211 231 252 270
Tap 4 253 278 307 325 348 374 397 415
First Stage “COOL” Speed
Tap 1 26 36 39 52 62 73 93 102
Tap 2 37 45 57 66 76 90 100 113
Tap 3 62 80 94 108 123 135 152 171
Tap 4 88 108 128 145 162 181 195 214
Second Stage “COOL
Speed
Tap 1 33 45 57 68 78 89 101 115
Tap 2 64 81 96 113 132 145 159 179
Tap 3 133 152 172 190 211 231 252 270
Tap 4 253 278 307 325 348 374 397 415
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
“HEAT” Speed
Tap 1 30 43 54 62 73 84 97 109
Tap 2 52 71 87 99 117 128 145 157
Tap 3 100 118 138 161 179 193 204 228
Tap 4 167 185 206 230 256 280 295 316
First Stage “COOL” Speed
Tap 1 23 29 42 48 60 75 88 93
Tap 2 31 39 54 62 76 86 96 105
Tap 3 46 56 70 84 93 107 115 133
Tap 4 72 87 105 121 141 158 175 188
Second Stage “COOL
Speed
Tap 1 30 43 54 62 73 84 97 109
Tap 2 52 71 87 99 117 128 145 157
Tap 3 100 118 138 161 179 193 204 228
Tap 4 167 185 206 230 256 280 295 316
BCE5V30 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
ADJUST”
Jumper Setting
Jumper Speed Positions
“HEAT” Speed (W) First Stage “COOL” Speed (Y1)
Second Stage “COOL” Speed (Y1
+ Y2)
1 2 3 4 1 2 3 4 1 2 3 4
cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm
+ 680 885 1115 1340 490 635 770 930 680 885 1115 1340
NORM 620 810 1020 1220 440 575 715 845 620 810 1020 1220
550 725 905 1100 411 530 645 755 550 725 905 1100
NOTES - The eect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System applica-
tions - minimum blower speed is 250 cfm.