BE5V Specifications Sheet

COMPACT AIR HANDLER
BE5V
Page 11
AT “NORM” SETTING (“Adjust” Jumper at NORM Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
“HEAT” Speed
Tap 1 116 146 168 196 221 250 286 305
Tap 2 188 215 243 266 295 319 348 383
Tap 3 270 300 327 353 384 417 450 474
Tap 4 375 416 459 500 517 556 588 618
First Stage “COOL” Speed
Tap 1 57 78 107 134 151 171 192 225
Tap 2 85 111 135 158 197 213 226 246
Tap 3 118 138 163 186 219 254 291 305
Tap 4 170 198 217 247 267 295 328 380
Second Stage “COOL
Speed
Tap 1 116 146 168 196 221 250 286 305
Tap 2 188 215 243 266 295 319 348 383
Tap 3 270 300 327 353 384 417 450 474
Tap 4 375 416 459 500 517 556 588 618
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
“HEAT” Speed
Tap 1 96 119 138 162 191 227 247 266
Tap 2 153 171 200 226 249 286 303 348
Tap 3 204 237 259 286 319 336 371 401
Tap 4 282 312 353 384 417 441 468 503
First Stage “COOL” Speed
Tap 1 56 74 98 121 131 169 178 200
Tap 2 79 93 115 140 165 188 199 218
Tap 3 98 117 138 170 196 228 250 260
Tap 4 126 148 175 194 222 254 300 322
Second Stage “COOL
Speed
Tap 1 96 119 138 162 191 227 247 266
Tap 2 153 171 200 226 249 286 303 348
Tap 3 204 237 259 286 319 336 371 401
Tap 4 282 312 353 384 417 441 468 503
BE5V48 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
ADJUST”
Jumper Setting
Jumper Speed Positions
“HEAT” Speed (W) First Stage “COOL” Speed (Y1)
Second Stage “COOL” Speed (Y1
+ Y2)
1 2 3 4 1 2 3 4 1 2 3 4
cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm
+ 1375 1600 1820 2185 960 1125 1285 1620 1375 1600 1820 2185
NORM 1260 1455 1655 2085 885 1035 1185 1475 1260 1455 1655 2085
1125 1310 1490 1885 790 925 1060 1330 1125 1310 1490 1885
NOTES - The eect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System
applications - minimum blower speed is 450 cfm.