BE5V Specifications Sheet
COMPACT AIR HANDLER
BE5V
Page 6
AT “–” (Minus) SETTING (“Adjust” Jumper at “–” Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
“HEAT” Speed
Tap 1 33 43 56 65 77 88 96 112
Tap 2 65 80 93 113 126 140 151 164
Tap 3 119 140 153 169 185 206 220 236
Tap 4 195 219 237 261 281 296 320 338
First Stage “COOL” Speed
Tap 1 23 35 43 52 63 73 85 96
Tap 2 37 45 54 70 76 86 99 110
Tap 3 59 73 86 102 113 128 140 152
Tap 4 88 102 119 137 154 165 185 201
Second Stage “COOL”
Speed
Tap 1 33 43 56 65 77 88 96 112
Tap 2 65 80 93 113 126 140 151 164
Tap 3 119 140 153 169 185 206 220 236
Tap 4 195 219 237 261 281 296 320 338
BCE5V24 BLOWER MOTOR WATTS
AT “+” (Plus) SETTING (“Adjust” Jumper at “+” Setting)
Jumper Speed Positions
Motor Watts @ Various External Static Pressures - in. wg.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
“HEAT” Speed
Tap 1 40 50 60 74 86 95 112 124
Tap 2 82 100 116 136 151 163 185 197
Tap 3 173 190 213 236 257 283 300 316
Tap 4 290 318 339 363 379 407 447 463
First Stage “COOL” Speed
Tap 1 27 37 46 57 68 76 88 104
Tap 2 41 54 62 75 87 97 108 121
Tap 3 75 94 109 127 145 161 173 191
Tap 4 113 133 146 168 189 205 222 244
Second Stage “COOL”
Speed
Tap 1 40 50 60 74 86 95 112 124
Tap 2 82 100 116 136 151 163 185 197
Tap 3 173 190 213 236 257 283 300 316
Tap 4 290 318 339 363 379 407 447 463
BCE5V24 BLOWER PERFORMANCE
0 through 0.80 in. w.g. External Static Pressure Range
“ADJUST”
Jumper Setting
Jumper Speed Positions
“HEAT” Speed (W) First Stage “COOL” Speed (Y1)
Second Stage “COOL” Speed (Y1
+ Y2)
1 2 3 4 1 2 3 4 1 2 3 4
cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm cfm
+ 450 670 900 1120 340 450 650 770 450 670 900 1120
NORM 420 620 820 1050 300 400 600 700 420 620 820 1050
– 390 570 750 915 280 390 500 650 390 570 750 915
NOTES - The eect of static pressure, filter and electric heater resistance is included in the air volumes listed.
First stage cooling air volume is 70% of COOL speed setting. Continuous blower speed is approximately 50% of COOL speed setting. Lennox Harmony III™ Zoning System
applications - minimum blower speed is 250 cfm.