Evaporator Coil Spec Sheet
EVAPORATOR COILS
Page 3
SPECIFICATIONS 1.5 TO 2 TON
General Data
Model No.
BC1P18/24 BC1P18/24B BC1P24A BC1P24B
Line
Connections
in.
Suction / vapor o.d. -
sweat
3/4 3/4 3/4 3/4
Liquid o.d. - sweat 3/8 3/8 3/8 3/8
Condensate drain (fpt) (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4
RFCIV metering device orifice size 0.053 0.053 0.057 0.057
Shipping Data - lbs.
Uncased 18 20 23 24
Cased 30 34 38 43
1
Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width.
SPECIFICATIONS 2.5 TO 3 TON
General Data
Model No.
BC1P30A BC1P30B BC1P30/36A BC1P30/36B
Line
Connections
in.
Suction / vapor o.d. -
sweat
3/4 3/4 3/4 3/4
Liquid o.d. - sweat 3/8 3/8 3/8 3/8
Condensate drain (fpt) (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4
RFCIV metering device orifice size 0.067 0.067 0.057 0.057
Shipping Data - lbs.
Uncased 31 32 26 27
Cased 45 50 41 45
1
Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width.
SPECIFICATIONS 2.5 TO 4 TON
General
Data
Model No.
BC1P30/36C BC1P36A BC1P36B BC1P48B BC1P48C
Nominal size - Tons 2.5 / 3 3 3 3.5 / 4 3.5 / 4
Line
Connections
in.
Suction / vapor o.d. -
sweat
3/4 3/4 3/4 7/ 8 7/ 8
Liquid o.d. - sweat 3/8 3/8 3/8 3/8 3/8
Condensate drain
(fpt)
(2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4 (2) 3/4
RFCIV metering device orifice size 0.057 0.070 0.070 0.071 0.071
Shipping Data - lbs.
Uncased 29 31 33 43 44
Cased 48 46 50 55 60
1
Uncased coils match furnaces without any overhang but require optional adaptor base or field fabricated transition to match furnace width.
BC1P