BC Evaporator Coil Specifications Sheets
Table Of Contents
Page
14
EVAPORATOR COILS
BH1P-18 Through BH1P-60
1
Optional right-hand airflow
requires a field fabricated
6 in. (152 mm) spacer
in-between the furnace and coil.
TOP VIEW
3/4
(19)
21-1/2
(546)
20
(508)
OPENING
C
3/4
(19)
3/4
3/4
(19)
3/4
(19)
SUCTION
LINE
B
E
A
LIQUID
LINE
H
G
10-3/4
1-3/4
(44)
9/16
(14)
B
21-1/2
(546)
20-3/8
(518)
D
OPENING
9/16
(14)
9/16
9/16
(14)
(19)
F
CONDENSATE
1-3/4
(44)
(273)
(14)
END VIEW
DRAINS
FRONT VIEW
END VIEW
Model No.
A
B
C
D
E
F
G
H
in. mm in. mm in. mm in. mm in. mm in. mm
in. mm
in. mm
BH1P-18A
26-1/2 673 14-1/2 368 13 330 13-3/8 340 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-24A
26-1/2 673 14-1/2 368 13 330 13-3/8 340 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-24B
26-1/2 673 17-1/2 444 16 406 16-3/8 416 4 102 2-1/8 54 3 76 4-7/8 124
BH1P
-30A 31-1/2 800 14-1/2 368 13 330 13-3/8 340 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-30B
26-1/2 673 17-1/2 444 16 406 16-3/8 416 4 102 2-1/8 54 3 76 4-7/8 124
BH1P
-36A 26-1/2 673 14-1/2 368 13 330 13-3/8 340 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-36B
26-1/2
673
17-1/2
444
16
406
16-3/8
416
4
102
2-1/8
54
3
76
4-7/8
124
BH1P-36C
26-1/2 673 21 533 19-1/2 495 19-7/8 505 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-42B
31-1/2
800
17-1/2
444
16
406
16-3/8
416
4
102
2-1/8
54
3
76
4-7/8
124
BH1P-42C
26-1/2 673 21 533 19-1/2 495 19-7/8 505 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-48B
31-1/2
800
17-1/2
444
16
406
16-3/8
416
4
102
2-1/8
54
3
76
4-7/8
124
BH1P-48C
26-1/2 673 21 533 19-1/2 495 19-7/8 505 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-51C
31-1/2 800 21 533 19-1/2 495 19-7/8 505 4 102 2-1/8 54 3 76 4-7/8 124
BH1P-60D
31-1/2 800 24-1/2 622 23 584 23-3/8 594 4 102 2-1/8 54 3 76 4-7/8 124
AIR
FLOW
1
OPTIONAL
AIR FLOW
PREFERRED
AIR FLOW