Maximum Allowable Exhaust Vent Lengths with Furnace Installed in a Closet or Basement Using Ventilated Attic or Crawl
Space for Intake Air in Feet
Standard Termination at Elevation 0 - 4,500 ft
Number of
90° Elbows
Used
2" Pipe 2-1/2" Pipe 3" Pipe
Capacity Capacity Capacity
045 070 090 110 045 070 090 110 045 070 090 110
1 66 51 29 9 95 95 73 38 113 112 93 93
2 61 46 24 4 90 90 68 33 108 107 88 88
3 56 41 19
n/a
85 85 63 28 103 102 83 83
4 51 36 14 80 80 58 23 98 97 78 78
5 46 31 9 85 75 53 18 93 92 73 73
6 41 26 4 70 70 48 13 88 87 68 68
7 36 21
n/a
65 65 43 8 83 82 63 63
8 31 16 60 60 38 3 78 77 58 58
9 26 11 55 55 33
n/a
73 72 53 53
10 21 6 50 50 28 68 67 48 48
Standard Termination Elevation 4,501 - 10,000 ft.
Number of
90° Elbows
Used
2" Pipe 2-1/2" Pipe 3" Pipe
Capacity Capacity Capacity
045 070 090 110 045 070 090 110 045 070 090 110
1 66 51 29
n/a
95 95 73 38 113 112 93 93
2 61 46 24 90 90 68 33 108 107 88 88
3 56 41 19 85 85 63 28 103 102 83 83
4 51 36 14 80 80 58 23 98 97 78 78
5 46 31 9 85 85 53 18 93 92 73 73
6 41 26 4 70 70 48 13 88 87 68 68
7 36 21
n/a
65 65 43 8 83 82 63 63
8 31 16 60 60 38 3 78 77 58 58
9 26 11 55 55 33
n/a
73 72 53 53
10 21 6 50 50 28 68 67 48 48
* Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
* Additional vent pipe and elbows used to terminate the vent pipe outside the structure must be included in the total vent length
calculation.
Table 5C.