BA13 Spec Sheet
SPLIT SYSTEM AIR CONDITIONER 4AC13
Page 2
MODEL NUMBER GUIDE
MINOR REVISION CODE
MAJOR REVISION CODE
ELECTRICAL
P = 1-PHASE, 208/230V, 60HZ
TONNAGE
18, 24, 30, 36, 42, 48, 60
REFRIGERANT
4 = R410A
AC
AIR CONDITIONER
SEER
13
TIER
B = WIRE GUARD
L = LOUVERED
4 AC 13 B/L 24 P - 11 A4 AC 13 B/L 24 P - 11 A
PHYSICAL AND ELECTRICAL DATA
Model
Voltage/Hz/
Phase
Voltage
Range
Min.
Circuit
Amp.
Max. Over
Current
Device
(amps)†
Compressor Outdoor Fan Motor
Rated
Load
(amps)
Locked
Rotor
(amps)
Rated
Load
(amps)
Rated
HP
Nom.
RPM
4AC13*18P-10 208-230/60/1 197-253 12.4 20 9.4 57 0.7 1/10 1010
4AC13*18P-11 208-230/60/1 197-253 12.4 20 9.4 57 0.7 1/10 1010
4AC13*24P-10 208-230/60/1 197-253 14.7 25 11.2 61 0.7 1/10 1010
4AC13*24P-11 208-230/60/1 197-253 14.7 25 11.2 61 0.7 1/10 1010
4AC13*30P-10 208-230/60/1 197-253 18.7 30 14.1 64 1.1 1/5 1090
4AC13*30P-11 208-230/60/1 197-253 17.1 25 12.8 68 1.1 1/5 1090
4AC13*36P-10 208-230/60/1 197-253 22.0 35 16.7 79 1.1 1/5 1090
4AC13*36P-11 208-230/60/1 197-253 20.4 35 15.4 84 1.1 1/5 1090
4AC13*42P-10 208-230/60/1 197-253 28.1 45 21.2 90 1.7 1/4 825
4AC13*42P-11 208-230/60/1 197-253 25.7 40 19.2 124 1.7 1/4 825
4AC13*48P-10 208-230/60/1 197-253 31.9 50 24.2 100 1.7 1/4 825
4AC13*48P-11 208-230/60/1 197-253 31.9 50 24.2 100 1.7 1 /4 825
4AC13*60P-10 208-230/60/1 197-253 34.7 60 26.4 125 1.7 1/4 825
4AC13*60P-11 208-230/60/1 197-253 34.7 60 26.4 125 1.7 1/4 825
* = B or L B = Wire Guard L = Louvered
† Overcurrent protection device
UNIT DIMENSIONS (IN.)
Model
Dimensions (inch) Weight (lbs.)
A -
Width
B -
Depth
C -
Height
Wire
Guard
Louvered
4AC13*18P-10/11 24.25 24.25 25 125 136
4AC13*24P-10/11 24.25 24.25 25 126 137
4AC13*30P-10/11 24.25 24.25 29 139 147
4AC13*36P-10/11 24.25 24.25 29 141 149
4AC13*42P-10/11 28.25 28.25 29 184 194
4AC13*48P-10/11 28.25 28.25 33 181 192
4AC13*60P-10/11 28.25 28.25 29 194 205
* = B or L B = Wire Guard L = Louvered
Note: Dimensions listed are unit sizes w/o packaging