BA13 Specifications Sheet
Table Of Contents
SPLIT SYSTEM AIR CONDITIONER
BA13
COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES
Page 14
Outdoor Model
Indoor
Model
Variable
Speed
Furnace
SEER
EER
Rated
ARI
1
Capacity
BTUH
Rated
Sensible
Capacity
BTUH
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Expansion
Device
Evaporator
Coil
or
3
Air Handler
Outdoor
Indoor
Suction
Liquid
2
Piston
TXV
Suction
Liquid
Suction
Liquid
BA13*42P
E(C,M,U)1P50C
95G1DF090CE16
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
0.075
A4TXV02
E(C,M,U)1P50C
95G1DF110CE20
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
E(C,M,U)1P50C
95G1UH090CE16
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
E(C,M,U)1P50C
95G1UH110CE20
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
E(C,M,U)1P50C
95G2DF090CV20
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
E(C,M,U)1P50C
95G2DF110CV20
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
E(C,M,U)1P50C
95G2UH090CV20
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
E(C,M,U)1P50C
95G2UH110CV20
13.5
11.5
40,000
29,200
1400
7/8
3/8
7/8
3/8
3/4
6
3/8
BA13*48P
BCS3M48C****P
BCE3M48C****P
13.00
11.00
47,000
34300
1600
7/8
3/8
7/8
3/8
7/8
3/8
0.082
A4TXV02
BCS2M48V****P
13.50
11.00
47,000
34300
1600
7/8
3/8
7/8
3/8
7/8
3/8
BCS3M48E****P
14.0
11.0
47,000
34300
1600
7/8
3/8
7/8
3/8
7/8
3/8
BA13*60P
BCS3M60C****P
BCE3M60C****P
13.00
11.00
57,000
41000
1800
7/8
3/8
7/8
3/8
7/8
7
3/8
0.090
A4TXV02
BCS2M60V****P
13.50
11.00
57,000
41000
1800
7/8
3/8
7/8
3/8
7/8
7
3/8
BCS3M60E****P
13.5
11.0
57,000
41000
1800
7/8
3/8
7/8
3/8
7/8
7
3/8
* = B or L B = Wire Guard L = Louvered
Note:
1
Ce
r
t
i
f
i
e
d
i
n
a
cc
o
r
d
a
n
c
e
w
i
t
h
U
n
i
t
a
r
y
A
i
r
C
o
n
d
i
t
i
o
n
e
r
Ce
r
t
i
f
i
c
a
t
i
o
n
P
r
og
r
a
m
,
w
h
i
c
h
i
s
b
a
s
e
d
o
n A
H
R
I
S
t
a
n
d
a
r
d
2
1
0
/
2
4
0
2
Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
3
A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products.
4 For lines 25 ft or over, use 3/8"
5 For lines 25 ft or over, use 3/4"