BA13 Specifications Sheet
Table Of Contents
Page 4
SPLIT SYSTEM AIR CONDITIONER
BA13
COOLING PERFORMANCE WITH EVAPORATOR COILS
Outdoor Model
Indoor
Model
SEER
EER
Rated
AHRI
1
Capacity
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor Metering
Device
Evaporator Coil3
or
3
Air Handler
Outdoor
Indoor
Suction
Liquid
2
Piston
TXV
Suction
Liquid
Suction
Liquid
BA13*18P
E(C,H,M,U)1P23(A,B)+TDR
13.00
11.00
17600
12800
650
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.053
A4TXV01
E(C,M,U)1P24(A,B)+TDR
13.00
11.00
17600
12800
650
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.053
A4TXV01
E(C,H,M,U)1P29A+TDR
13.00
11.00
17600
12800
650
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.053
A4TXV01
BA13*24P
E(C,H,M,U)1P23(A,B)+TDR
13.00
11.00
22800
16800
800
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.057
A4TXV01
E(C,M,U)1P24(A,B)+TDR
13.00
11.00
22800
16800
800
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.057
A4TXV01
E(C,H,M,U)1P29A+TDR
13.00
11.00
22800
16800
800
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.057
A4TXV01
E(C,M,U)1P30(A,B)+TDR
13.00
11.00
22800
16800
800
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.057
A4TXV01
E(C,H,M,U)1P36(A,B,C)+TDR
13.00
11.00
22800
16800
800
5/8
3/8
3/4
3/8
5/8
5
3/8 or 1/4
4
0.057
A4TXV01
BA13*30P
E(C,H,M,U)1P23(A,B)+TDR
13.00
11.00
28000
20400
1000
3/4
3/8
3/4
3/8
3/4
3/8
0.063
A4TXV01
E(C,M,U)1P24(A,B)+TDR
13.00
11.00
28000
20400
1000
3/4
3/8
3/4
3/8
3/4
3/8
0.063
A4TXV01
E(C,H,M,U)1P29A+TDR
13.00
11.00
28000
20400
1000
3/4
3/8
3/4
3/8
3/4
3/8
0.063
A4TXV01
E(C,M,U)1P30(A,B)+TDR
13.00
11.00
28000
20400
1000
3/4
3/8
3/4
3/8
3/4
3/8
0.063
A4TXV01
E(C,H,M,U)1P36(A,B,C)+TDR
13.00
11.00
28000
20400
1000
3/4
3/8
3/4
3/8
3/4
3/8
0.063
A4TXV01
BA13*36P
E(C,H,M,U)1P36(B,C)+TDR
13.00
11.00
34000
25000
1200
3/4
3/8
7/8
3/8
3/4
6
3/8
0.072
A4TXV01
E(C,H,M,U)1P43(B,C)+TDR
13.00
11.00
34000
25000
1200
3/4
3/8
7/8
3/8
3/4
6
3/8
0.072
A4TXV01
E(C,H,M,U)1P50C+TDR
13.00
11.00
34000
25000
1200
3/4
3/8
7/8
3/8
3/4
6
3/8
0.072
A4TXV01
BA13*42P
E(C,H,M,U)1P43C+TDR
13.00
11.00
40000
29200
1400
3/4
3/8
7/8
3/8
3/4
6
3/8
0.075
A4TXV01
E(C,H,U)1P49C+TDR
13.00
11.00
40000
29200
1400
3/4
3/8
7/8
3/8
3/4
6
3/8
0.075
A4TXV01
E(C,H,M,U)1P50C+TDR
13.00
11.00
40000
29200
1400
3/4
3/8
7/8
3/8
3/4
6
3/8
0.075
A4TXV01
BA13*48P
E(C,H,U)1P49C+TDR
13.00
11.00
47000
34300
1600
7/8
3/8
7/8
3/8
7/8
3/8
0.082
A4TXV02
E(C,H,U)1P62C+TDR
13.00
11.00
47000
34300
1600
7/8
3/8
7/8
3/8
7/8
3/8
0.082
A4TXV02
E(C,H,U)1P62D+TDR
13.00
11.00
47000
34300
1600
7/8
3/8
7/8
3/8
7/8
3/8
0.082
A4TXV02
BA13*60P
E(C,H,U)1P49C+TDR
13.00
11.00
57000
41000
1800
7/8
3/8
7/8
3/8
7/8
7
3/8
0.090
A4TXV02
E(C,H,U)1P62C+TDR
13.00
11.00
57000
41000
1800
7/8
3/8
7/8
3/8
7/8
7
3/8
0.090
A4TXV02
E(C,H,U)1P62D+TDR
13.00
11.00
57000
41000
1800
7/8
3/8
7/8
3/8
7/8
7
3/8
0.090
A4TXV02
1
Ce
r
t
i
f
i
e
d
i
n
a
cc
o
r
d
a
n
c
e
w
i
t
h
U
n
i
t
a
r
y
A
i
r
C
o
n
d
i
t
i
o
n
e
r
Ce
r
t
i
f
i
c
a
t
i
o
n
P
r
og
r
a
m
,
w
h
i
c
h
i
s
b
a
s
e
d
o
n A
H
R
I
S
t
a
n
d
a
r
d
2
1
0
/
2
4
0
.
2
Required to achieve AHRI rating.
* = B or L B = Wire Guard L = Louvered
Note:
1
Ce
r
t
i
f
i
e
d
i
n
a
cc
o
r
d
a
n
c
e
w
i
t
h
U
n
i
t
a
r
y
A
i
r
C
o
n
d
i
t
i
o
n
e
r
Ce
r
t
i
f
i
c
a
t
i
o
n
P
r
og
r
a
m
,
w
h
i
c
h
i
s
b
a
s
e
d
o
n A
H
R
I
S
t
a
n
d
a
r
d
2
1
0
/
2
4
0
2
Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
3
A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products.
4 For lines 25 ft or over, use 3/8"
5 For lines 25 ft or over, use 3/4"
6 For lines 25 ft or over, use 7/8"
7
F
o
r
li
n
e
s
25
ft
o
r
o
v
e
r
,
u
s
e
1
-
1
/8
"