BA13 Specifications Sheet
Table Of Contents
Page 2
SPLIT SYSTEM AIR CONDITIONER
BA13
ELECTRICAL AND PHYSICAL DATA
Model
Voltage/
Hz/
Phase
Voltage
Range
Min.
Circuit
(Amps)
Max. Fuse
(Amps)†
Compressor
Fan Motor
Refrig.
Charge
(oz.)† †
Weight (lbs.)
Rated
Load
(Amps)
Locked
Rotor
(Amps)
Full Load
(Amps)
Rated
HP
Nom.
RPM
Wire
Guard
Louvered
BA13*18P
208-230/60/1
197-253
10.9 15
8.1
39
0.7
1/10
1010
62
125 136
BA13*24P
208-230/60/1
197-253
14.1
20
10.7
53
0.7
1/10
1010
63
126 137
BA13*30P
208-230/60/1
197-253
15.6
25
11.6
59
1.1
1/5
1090
82
139 147
BA13*36P
208-230/60/1
197-253
20.1
35
15.2
70
1.1
1/5
1090
84
141
149
BA13*42P
208-230/60/1
197-253
28.1
45
21.1
90
1.7 1/4
825
104
184 194
BA13*48P
208-230/60/1
197-253
31.9
50
24.1
100
1.7 1/4
825
124
181
192
BA13*60P
208-230/60/1
197-253
29.4
60
22.1 120 1.7 1/4
830
144 194
205
† Overcurrent protection device
† † Factory charge adequate for 15 feet of line set. Adjust per
Installation Instructions.