Use and Care Manual
7
ATTENTION LICENSED ELECTRICIANS
STANDARD WIRING FOR 220V
— See Motor Label for Details —
If you are connecting your Pump to a 220V power source follow these
simple directions. Remove the rear housing to expose the electric connection plate
Your New Pump is pre-wired for 220V operation
You will attach the 2 power supply wires and the ground wires as
indicated below
One on the 2 power wires-line 1 (doesn’t matter which one or what
color) connects to the Top left connection hub — you can use a clip
and slide it on or loosen the nut and attach the wire direct to the port
Connect second power wire (line 2) to the connection hub to the
right of the first connection. Again you can slide on a clip connection
or loosen the nut and attach the wire direct. Once again the color of
the line in does not matter
Attaching the ground wire (green) Take the 3rd wire from your power
source (green) and attach it to the grounding screw located at the
center of the motor
Replace the housing cover
1
2
3
4
5
6
4
3
5