User Guide

7
DO NOT BLOCK SUCTION
RISK OF ELECTRICAL SHOCK
1. Pump suction is dangerous and can trap and drown or disembowel bathers.
2. Blocking suction with body may cause severe and/or fatal injury
3. Do not operate swimming pools, spas or hot tubs if a suction outlet cover is
missing, broken or loose
4. Suction outlet must be replaced if cracked, broken or missing.
5. All suction outlets must have correctly installed screw fastened covers in place.
1. To avoid dangerous or fatal electrical shock, TURN OFF power to motor
BEFORE working on electrical connections.
2. To reduce the risk of electrical shock, unplug motor before working on pump
or motor.
WARNING
PUMP MAINTENANCE
WINTERIZATION
The pump requires little to no maintenance other than reasonable care and
cleaning of the strainer basket on a regular basis. The pump is equipped with a
mechanical seal. This seal may eventually come loose of a period of time,
depending on running time and water quality. If water continually leaks out, a new
mechanical seal should be installed
See parts diagram for seal location
The pump is equipped with a rubber O-Ring that seals the strainer basket lid. This
O-Ring should be lubricated with water proof lubricant
(O-RING LUBE) to ensure proper seal and extend O-Ring life. If O-Ring becomes
cracked or worn (flattened) is will become necessary to replace
In areas subject to freezing temperatures, it is recommended that the pump be
disconnected and stored indoors in a warm and dry location. Remove the drain
plugs from the pump housing and place them in the strainer basket for storage.