Installation Guide
10
5. OPERATION INSTRUCTIONS
1. The lter pump is self-priming as long as it is positioned at least 7 to 8 inches below the highest
water level of the lower hose connection. An air relief valve is located on the top of the pump. Turn
the valve knob counter-clockwise, allowing air to escape from the tank. When a small amount of water
escapes, close immediately. The pump is now completely primed.
2.
CAUTION! Never operate the lter pump dry. This can cause damage to pump seals resulting in
leakage and/or ooding. Dry running damage is not covered by the warranty.
3. Prior to each use, check to ensure that all hose-clamps are tightened.
4. The lter pump must operate in the upright, vertical position.
5. The lter pump must be positioned on level, stable ground.
6. To keep the pool ltered properly, your pump should be run approximately 4 to 6 hours per day.
Overuse may cause overheating and/or motor burnout. Use good judgment on extremely hot days.
7.
DO NOT run the lter pump continuously for an extended period of time.
6. CLEANING & REPLACEMENT
1. The lter media in your pump lter system should be inspected and cleaned or replaced when dirty
or at least at the start of each new season.
2. Periodical cleaning of your lter media can enhance the effectiveness of your lter pump and
prolong the lter media’s lifespan prior to replacement.
3.
WARNING! Always disconnect the power to the unit when cleaning or changing the lter media.
4. Cleaning or changing the lter media:
• Plug the intake tting on the side of the pool or if equipped with a shut off valve, close it to
prevent water from escaping from the lter tank when you remove the lter canister cover.
• Turn the air relief screw to release the air suction inside.
• Remove the lter canister cover and the lter chamber rubber gasket.
• Remove the dirty lter media and the black foam screen from the lter canister.
• Rinse dirt and debris from the black foam screen and return to the lter canister.
• Rinse and clean the lter media or replace with a new lter media and return to the lter
canister on top of the black foam screen.
• Reassemble the lter canister cover, remove the wall plug and open the shut off valve to
allow water to enter the lter pump until water comes out of the air relief screw. Then, tighten
the air relief screw.
5. Now, reconnect the lter pump to the power supply and resume ltering operation.