Instructions / Assembly
adaptor as Figure 9
For new pool
This light could be used as the returning fitting. Install the wall flange, gasket and
octagonal nut as usual. See Figure
Install the light following above procedure from step 3 to 11.
SECTION Ⅲ REPLACING
When the LED failed
Disconnect the quick connector on the wire and unscrew the light assembly head from the
wall flange and install a new one.
Warning: Please do not open the light assembly head. Open the head would avoid
the warranty.
When the transformer failed
Disconnect the quick connector on the wire and install a new transformer.
SECTION Ⅳ STORAGE AND WINTERIZING INSTRUCTIONS
1. It is common practice to drain the water level to a point below the skimmer and the
light, for winterizing
2. For storable pools: remove power from the unit by taking the power cords’
three-prong plug and disconnecting it from its electrical outlet.
For permanent pools: turn off all electrical power supplying the light circuit at the
main circuit breaker.
3. Disconnect the quick connector on the wire and unscrew the light assembly head from
the wall flange and store it for next season.
SECTION Ⅴ TECHNICAL DATA