INSTALLATION AND OPERATION MANUAL GAS TARGET TOP / STATIC OVEN RANGE G570 For use in GB & IE 230096-2
Contents Blue Seal Gas Target Top Static Oven Range G570 Gas Target Top Static Oven Range. Introduction..............................................................................................2 Specifications............................................................................................3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions................................................................................................
Introduction We are confident that you will be delighted with your BLUE SEAL Target Top Gas Static Oven Range, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important things you can do. Firstly: Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Specifications Model Numbers Covered in this Specification G570 Gas Target Top Static Oven Range. General A commercial heavy duty, general purpose fully modular, gas fired Target Top Static Oven Range, having a high output, two stage double-ring iron cast burner offering accurate temperature control and infinitely variable heat with the heat radiating out from the centre of the Target Top. The Main Burner is located underneath removable cast target top plates.
Specifications Gas Connection Gas supply connection point is located 130mm from the right hand side, 32mm from the rear and 655mm from the floor and is reached from beneath the appliance. (Refer to the ‘Dimensions’ section). Connection is ¾" BSP male thread.
Dimensions G570 5
Installation Installation Requirements NOTE: • It is most important that this appliance is installed correctly and that operation is correct before use. Installation shall comply with local gas and health and safety requirements. • This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of health harmful substances in the room, the appliance is installed in.
Installation Clearances Left/Right Hand Side Rear Combustible Surface 50 mm 50 mm Non Combustible Surface 0 mm 0 mm NOTE: Only non-combustible materials can be used in close proximity to this appliance. Assembly NOTE: • All Models are delivered completely assembled. No further assembly is required. Refer to the information below for assembly instructions. • This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level.
Installation NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line. 4. 5. 6. Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs so that the appliance is level and at the correct height. Connect the gas supply to the appliance. A suitable joining compound which resists the breakdown action of LPG must be used on every gas line connection, unless compression fittings are used.
Operation Operation Guide C AUTION : • This appliance is for professional use and is only to be used by qualified people. • Only authorised service persons should be used to carry out installation, servicing or gas conversion operations. • Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user/operator. 1. 2. Blue Seal appliances have been designed to provide simplicity of operation and 100% safety protection.
Operation Lighting the Pilot Burner - (Target Top) 1. Remove centre casting with the casting removal tool. 2. Depress the control knob and rotate anti-clockwise to the ‘PILOT’ position. 3. With the control knob depressed, manually light the pilot burner located in front of the main burner. 4. Hold in the control knob for approximately 10 to 15 seconds, then release. 5. The pilot burner should remain alight. If not repeat Items 2 to 4 above until the pilot burner lights.
Operation Lighting the Pilot Burner - (Oven) This oven is fitted with a pilot as a standard option and Flame Failure Protection, which is incorporated by way of a thermo-electric system for the main burner. Flame Failure Protection will shut off the gas supply to the burner in the event that the pilot burner goes out, so that un-burnt gas is not expelled. This is an . important safety feature which is slowly becoming law throughout the world ! IMPORTANT 1. 2. 3. 4. 5.
Cleaning and Maintenance CAUTION: Always turn 'Off' the gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. General Clean the Target Top regularly. A clean appliance looks better, will last longer and will perform better. Carbonised grease on the cooking surface will hinder the transfer of heat from the cooking surface to the food. This will result in loss of cooking efficiency.
Cleaning and Maintenance c. DO NOT use water on the castings while they are still hot as cracking may occur. Should it be necessary to clean the castings, allow the castings to cool and then remove for cleaning. Clean using a soft cloth moistened with a mild detergent and hot water solution and a scrubbing brush. Dry thoroughly with a dry cloth. d. Remove the drip tray and clean with a mild anti bacterial detergent and hot water solution using a soft bristled brush.
Fault Finding This section provides an easy reference guide to the more common problems that may occur during the operation of your appliance. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your appliance. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure CAUTION: Ensure that the Unit is isolated from the gas supply before commencing servicing. NOTE: • These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. • For all relevant gas specifications refer to the ‘Specifications’ table at the end of this section. Target Top - Main Burner 1. 2. 3. 4. 5. 6. 7. Remove the control knob from the front control panel.
Gas Conversion and Specifications Target Top - Pilot Burner 1. 2. 3. 4. 5. 6. To remove the pilot burner, disconnect the gas supply tube from the base of the pilot burner. Remove the bolt securing the retaining plate holding the pilot burner and thermo couple to the mounting bracket. Remove the retaining plate. The pilot burner can now be removed from the mounting bracket. Unscrew the base nut from the pilot burner and withdraw injector and spring from inside the pilot burner.
Gas Conversion and Specifications Oven 1. 2. 3. 4. 5. 6. 1. 2. 3. 4. 5. Injector: With the gas supply turned off at the main supply, unscrew and remove the 6 screws securing the lower lintel to the front of the oven. Open the oven door and remove the vitreous enamelled tray from inside the oven. Remove the 2 screws securing the oven burner in the oven and remove the main burner from the oven. The main injector will now be exposed and can be 1/ unscrewed and removed using a 13mm ( 2” A/F) spanner.
Gas Conversion and Specifications Gas Regulator NOTE: The regulator supplied is convertible between Natural Gas and LPG, but it’s outlet pressure is fixed ex-factory and is NOT to be adjusted. NOTE, Pin rotated for Natural Gas NOTE, Pin rotated for LPG Fig 21 1. 2. 3. 4. Ensure that the gas supply is turned ‘OFF’ at the mains. Unscrew the hexagonal cap (23mm A/F) from the regulator.
Gas Conversion and Specifications Gas Specifications - Non-UK Only Nat. Gas Target Top Oven LP Gas (Propane) Main Burner Injector (Inner Ring) Ø 1.70 mm Ø 1.10 mm Main Burner Injector (Outer Ring) Pilot Burner Injector Burner Aeration Screw X (Inner) Burner Aeration Screw Y (Outer) Low Fire Adjustment Main Burner Pilot Burner Low Fire Screw Ø 2.60 mm 0.35 25 mm 28 mm 2½ turns out (ccw) Ø 2.60 mm 0.35 Ø 1.5 mm Ø 1.55 mm 0.25 25 mm 28 mm 1 turn out (ccw) Ø 1.60 mm 0.23 Ø 0.95 mm 1.00 kPa (*) 2.
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for the servicing and repair of this appliance. The instructions supplied with the parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service branch (contact details are as shown on the reverse of the front cover of this manual).
Replacement Parts List General 227012 227013 014997 227892 227893 227896 227850 229674 Centre Half Oven Rear Casting. Plate Casting. Casting Removal Tool. Oven Side Rack LH. Oven Side Rack RH. Rack. Adjustable Leg (150 mm) Roller Assy. Accessories 228800 Ranges 900 mm Plinth Kit. Utensils Direct 0845 873 6600 www.utensilsdirect.co.