INSTALLATION AND OPERATION MANUAL GAS TARGET TOP G57 232417-8
MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: E.Mail: Main Office: Service: Spares: Customer Service: www.moffat.com.au vsales@moffat.com.au (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3833 (tel): 1800 622 216 (tel): 1800 337 963 (tel): 1800 335 315 (fax): 1800 350 281 CANADA Serve Canada Web: E.Mail: Sales: Service: www.servecanada.com info@servecanada.
Contents Blue Seal Gas Target Top G57 Target Top - 900mm. Introduction ............................................................................................. 2 Specifications ........................................................................................... 3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions ................................................................................................ 4 Weight Installation ..............
Introduction We are confident that you will be delighted with your BLUE SEAL TARGET TOP, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Blue Seal Target Top, there are two important things you can do. Firstly: Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Specifications Model Numbers Covered in this Specification G57 - LS Gas Target Top, 900mm wide Hob on Leg Stand. G57 - B Gas Target Top, 900mm wide Bench Mount Hob. G57 - CB Gas Target Top, 900mm wide Hob with Base Cabinet. G57 - RB Gas Target Top, 900mm wide Hob to fit on Refrigeration Base Unit.
Dimensions G57-B Rating Plate Location Gas Connection Point. Weight (Nett) G57 - B 160 kg.
Dimensions G57-LS Rating Plate Location Gas Connection Point. Weight (Nett) G57 - LS 180 kg.
Dimensions G57-CB Rating Plate Location Gas Connection Point. Weight (Nett) G57 - CB 200 kg.
Dimensions G57-RB Rating Plate Location (View through slots in door) Electrical Connection Point. Gas Connection Point. Weight (Nett) G57 - RB 240 kg (Including the Refrigeration Cabinet.
Installation Installation Requirements NOTE: It is most important that this Target Top is installed correctly and that operation is correct before use. Installation shall comply with local gas, health and safety requirements. This appliance shall be installed with sufficient ventilation to prevent occurrence of unacceptable concentrations of health harmful substances in the room, the appliance is installed in.
Installation 7. If Target Top is fitted with a Refrigeration Cabinet, cabinet must NOT be installed in an explosive environment, open air or exposed to rain. The following considerations should be made; Cabinet must be located away from heat sources (radiators ovens and other heat generating kitchen appliances) and direct sunlight. Must be protected from draughts. Air circulation around condensing unit must not be obstructed.
Installation Fitting Leg Stand to Target Top Caution To prevent equipment damage and risk of injury, remove all castings, fire bricks and other removable items prior to fitting leg stand. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Remove centre casting from target top using casting removal tool, also remove 2 half plate castings. Remove all fire bricks from target top. Lower target top onto it’s rear face. Attach four hob legs to leg mounting positions on underside of target top. Secure each leg hand tight.
Installation Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON. 1. 2. Blue Seal Target Tops do not require an electrical connection, as they function totally on gas supply only. It is essential that gas supply is correct for target top to be installed and that adequate supply pressure and volume are available. The following checks should be made before installation:a.
Installation 7. Check gas operating pressure is as shown in 'Specifications' section. NOTE: Measure Burner operating pressure at target top hob manifold test point with target top burner (Inner and outer ring) operating at full setting. 8. 9. 10. Turn ‘Off’ mains gas supply and bleed gas out of appliance gas lines. Turn ‘On’ gas supply and appliance. Verify operating pressure remains correct.
Operation Operation Guide Caution This appliance is for professional use and is only to be used by qualified persons. Only authorised service persons are to carry out installation, servicing or gas conversion operations. Components having adjustments protected (e.g. paint sealed) manufacturer should not be adjusted by the user / operator. 1. 2. by the Blue Seal target tops have been designed to provide simplicity of operation and 100% safety protection.
Operation Lighting Pilot Burner 1. Remove centre casting with casting removal tool. 2. Push-in control knob and rotate anti-clockwise to PILOT position. 3. With control knob depressed, manually light pilot burner located in front of main burner. 4. Hold in control knob for approximately 10 to 15 seconds, then release. 5. Pilot burner should remain alight. If not repeat Items 2 to 4 above until pilot burner lights. Lighting Main Burner 1.
Cleaning and Maintenance General Caution Always turn ‘Off’ gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. Clean Target Top regularly. A clean appliance looks better, will last longer and will perform better. Carbonised grease on cooking surface will hinder transfer of heat from cooking surface to food. This will result in loss of cooking efficiency.
Cleaning and Maintenance c. DO NOT use water on castings while they are still hot as cracking may occur. Should it be necessary to clean castings, allow castings to cool and then remove for cleaning. Clean using a soft cloth moistened with a mild detergent and hot water solution and a scrubbing brush. Dry thoroughly with a dry cloth. d. Remove drip tray and clean with a mild anti bacterial detergent and hot water solution using a soft bristled brush. Dry drip tray thoroughly with a dry cloth. e.
Fault Finding This section provides an easy reference guide to the more common problems that may occur during operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure Caution Ensure Appliance is isolated from gas and electrical supplies before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning appliance. Adjustment of components that have adjustments / settings sealed (e.g.
Gas Conversion and Specifications NOTE: Ensure pilot burner and thermocouple are correctly located and pilot burner aligns with main burner ignition port. (Refer to figure opposite for correct fitting and alignment dimensions). Pilot Burner Thermocouple Main Burner Ignition Port 2± 2.0 18± 2.0 Re-connect gas supply tube to pilot burner. Refit RH main fire brick. Refit 2 front fire bricks. Refit 2 half plate castings - ensure they are correctly interlocked. Refit centre casting.
Gas Conversion and Specifications Gas Type Identification Label On completion of gas conversion, replace gas type identification label, located at:- Rear of the unit, above gas connection. - Beside the Rating Plate. Commissioning Before leaving the installation; 1. Check all gas connections for leakages using soapy water or other gas detecting equipment. DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES. 2. Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
Gas Conversion and Specifications Gas Specifications Natural Gas LP Gas Butane Town Gas (**) Main Burner Injector (Inner Ring) Ø 1.70 mm Ø 1.10 mm Ø 1.00 mm Ø 4.20 mm Main Burner Injector (Outer Ring) Ø 2.60 mm Ø 1.55 mm Ø 1.45 mm Ø 6.30 mm Pilot Injector 0.35 0.25 0.70 Burner Aeration Screw X (Inner) 25 mm 25 mm 20 mm Burner Aeration Screw Y (Outer) 28 mm 28 mm 22 mm 21/2 turns out (ccw) 1 turn out (ccw) Blank 11/2 turns out (ccw) 1.0 kPa (*) 2.6 kPa (*) 0.
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual). When ordering replacement parts, please quote part number and description as listed below.
Replacement Parts List Gas Regulators Gas Type Gas Regulators Part No. Description Nat. Gas LPG Butane 228531 ¾” BSP F/F Convertible. Town Gas 230185 ¾” BSP F/F Adjustable. Accessories 228801 228799 Refrigerator Base Plinth Kit. Cabinet Base / Leg Stand 900mm Plinth Kit. Gas Conversion Kits Model G57 Gas Type to Convert to Nat.