INSTALLATION
It is most important that the unit is installed correctly and that the operation is correct
before use. Installation must comply with local electric, health and safety requirements.
BEFORE CONNECTION TO POWER SUPPLY
Unpack the fryer and check for damage. Report any damage to the carrier within 7 days
or receipt of the goods. Report any deficiencies to the dealer.
Remove fryer from the pallet and remove all packing. Carefully place fryer onto its back
and fit the adjustable legs to the fryer and secure in place with spring washers and hex
bolts. Ensure that the bolts are securely tightened.
Position the fryer in its allocated working space and adjust the feet to the level the fryer
front to back and side to side.
This appliance must be installed with a minimum clearance of 25mm at rear and 50mm at
sides from combustible surfaces.
ELECTRICAL REQUIREMENT
The E603 and E604 are to be connected to a 230-240 volt AC 3 phase and Neutral, and
Earth supply. Each fryer tank has a total loading of 17 kW. Each of the three phases
has a loading of 5.66 kW 23.6 Amperes at 240 volts.
CONNECTION
The supply terminal connections are located at the lower front of the fryer. Remove the
service panel (screws on underside of chassis) to allow connection access for the
electrical supply. Bring the supply cable up through the compression type gland provided
on the rear of the main electrical switchgear panel. Connect mains supply to L1, L2 and
L3 fuse carrier connections for 3 phases. Connect neutral and earth conductors to
neutral stud and earth stud respectively. For all connections ensure that conductors are
secure and appropriately terminated. Tighten the cable gland to secure against tension
on the cable.
Each fryer should be connected to an adequately protected power supply and isolation
switch mounted adjacent to, but not behind the fryer. This switch must be clearly marked
and readily accessible in case of fire.
The fryer is equipped with 32A fusing on L1, L2 and L3 supplies. Ensure fuses are fitted
(type F1(NS) gG).