Specifications
7
Assembly
All Models
All models come pre-assembled.
NOTE: This appliance is fitted with adjustable feet to enable the unit to be positioned securely and
level. This should be carried out on completion of the electrical connection. Refer to
“Electrical Connection” section.
Optional Accessories (Refer to Replacement Parts List)
•
Plinth Kit. For installation details, refer to the instructions supplied with each kit.
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN AUTHORISED
PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch must be clearly marked and readily accessible in
case of fire.
1. Check that the electricity supply is correct as shown on the Rating
Plate attached to the lower front
hand side of the front sill panel.
2. The supply terminal connections are located at the rear of the the
appliance. Refer to ‘Electrical Connections’ in the ‘Specifications’
section of the manual.
3. Open the door and remove the control panel to allow connection
access for the electrical supply.
4. Bring the supply cable up through the compression type gland
provided on the rear of the main electrical switchgear panel.
5. Connect the mains supply to L1, L2 and L3 connections for 3
phases. Refer to the 'Electrical Supply Requirements' section for
connection details.
6. Connect neutral and earth conductors to neutral stud and earth
stud respectively.
7. For all connections ensure that conductors are secure and
appropriately terminated.
8. Tighten the cable gland to secure against tension on the cable.
NOTE:
•
This appliance must be earthed.
•
Fixed wiring installations must incorporate an all-pole disconnection switch.
9. Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
10. Connect the power supply to the appliance.
11. Check that the electrical supply is as shown in “Specifications” section.
Installation
WARNING:
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
C
AUTION
:
•
This appliance is for professional use and is to be used by qualified
persons only.
•
Only qualified service persons are allowed to carry out installation and
servicing of this appliance.
Fig 1
Rating Plate
Location