EF30 / EF35 / EF40 FRYER FILTER.
MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited E.Mail: vsales@moffat.com.au Main Office: (tel): +61 (03) 9518 3888 (fax): +61 (03 9518 3833 Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281 CANADA Serve Canada Web: E.Mail: Sales: Service: www.servecanada.com info@servecanada.com (tel): 800 551 8795 (Toll Free) (tel): 800 263 1455 (Toll Free) NEW ZEALAND Moffat Limited Web: E.
Filtamax Fryer Filter Contents Page Introduction ....................................................................................................... 5 Specifications .................................................................................................... 6 Installation ......................................................................................................... 9 Before Checking Operation Electrical Supply Installation / Storage Operation .......................................
-4-
INTRODUCTION Filtering oil is essential to maintain consistent high food quality, extend oil life, prevent smoking and saving on costs. "Filtamax" complements your Blue Seal Single and Twin pan fryers, providing a truly affordable filtration system with unique space saving and mobility features. Storage "Filtamax" is housed conveniently below your Vee-ray fryer (30/40 models), utilising the otherwise wasted space, refer specifications, pages 6-8.
SPECIFICATIONS 562 1 E 112 E 339 1 391 956 Model: EF30 ELECTRICAL ENTRY Front Side 683 324 1 E 34 Plan Electrical Connection 110/120V, 60Hz, 1P+N+E, 6.4A 220/240 V, 50 Hz, 1P+N+E, 3.
SPECIFICATIONS 562 1 E 112 E 390 1 450 956 Model: EF35 ELECTRICAL ENTRY Front Side 735 324 1 E 34 Plan Electrical Connection 110/120V, 60Hz, 1P+N+E, 6.4A 220/240 V, 50 Hz, 1P+N+E, 3.
SPECIFICATIONS 561 1 E 124 E 344 1 395 957 Model: EF40 ELECTRICAL ENTRY Front Side 683 474 1 E 34 Plan Electrical Connection 110/120V, 60Hz, 1P+N+E, 6.4A 220/240 V, 50 Hz, 1P+N+E, 3.
INSTALLATION It is most important that the filter is checked and that the unit is operating correctly before handing over to the user. Before Checking Operation Unpack and check unit for damage and report any damage to the carrier and supplier. Report any deficiencies to your supplier. Check that the unit has been supplied with the following: 1 x Filter Bag 1 x Filter Bag Frame 1 x Return Delivery Tube Electrical supply Check that the available power supply is suitable.
OPERATION WARNING ALWAYS TURN FRYER OFF BEFORE USING FILTER MACHINE DO NOT USE FILTER MACHINE AS AN OIL STORAGE VESSEL NEVER STORE FILTER MACHINE UNDER FRYER WITH OIL IN FILTER MACHINE ALWAYS USE PROTECTIVE GEAR WHEN FILTERING HOT OIL Preparation of Fryer 1. For safe working practice the fryer should only be filtered with the oil temperature between 120° - 150°C. 2. Always ensure the fryer is turned off when filtering. 3.
OPERATION 6. Unwind electrical supply cord of Filtamax filter from around cord hanger and plug into correct electrical supply. Ensure filter control switch is in the “Off“ position before turning electrical supply on. 7. Switch on electrical supply. 8. Push Filtamax filter unit back into cabinet so that the filter bag drain guard is positioned over the drain valve of the fryer. 9.
OPERATION 23. The residual oil now left in the base of the filter tank should now be mopped out and the filter tank cleaned out dry. Do not use a soapy solution to wash out the filter tank as soap is alkaline based and it is alkali’s that are responsible for rapid oil breakdown. 24.
CARBON FILTER PADS - OPTION Filter Pad - Option With Supersorb Carbon pads you can achieve even better quality by removing particles 30-50 times smaller than can be removed with standard filtering methods. Which means food can be cooked more efficiently, it tastes better, and you will benefit from reduced oil replacement costs. If it is desired to use carbon filter pads, then the Filter Pad Kit (part 025669) is required.
CARBON FILTER PADS - OPTION 4) Fit filter clamp over filter and lock into place by rotating handle (refer figure D). 5) Place strainer frame on filter unit (refer figure E), Filter is ready for use. Filter Clamp Frame in filtering position Figure D. Figure E. Filter Pad Replacement Filter pads should be replaced daily to maintain filtering efficiency and to ensure good hygiene. Filter unit must be empty.
CLEANING INSTRUCTIONS Exterior Clean with detergent. You may require to use a good quality stainless steel cleaner or stainless steel wool for heavy duty cleaning. Always apply cleaner when the filter is cool and rub in the direction of the “grain”. Do not use detergent or stainless steel cleaner on inside of filter tank. Interior Refer to the operating instructions for filter tank cleaning necessary after each filter.
TROUBLE SHOOTING ENSURE POWER IS SWITCHED OFF BEFORE SERVICING. All servicing should be carrier out by a competent electrical serviceman. FAULT Motor/Pump will not operate (no motor/pump noise). CAUSE No power to unit. REMEDY Check supply cord connection. Check power supply is on. Check power is available at supply. Motor overload protection has tripped. Motor/Pump will not operate Motor / Pump stalled. (motor/pump makes noise but will not pump oil/shortening). Blockage in pump or delivery system.
WIRING DIAGRAM 110 - 120V, 60Hz, 1P+N+E, 6.
WIRING DIAGRAM 220 - 240V, 50Hz, 1P+N+E, 3.
SPARE PARTS EF30 / EF35 / EF40 FRYER FILTER Part No.
-20-
-21-