User guide

CAUTION symbol refers to a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury.
WARNING symbol refers to a potentially hazardous situation which, if not avoided, may
result in death or serious injury.
Instructions
PN 7635 / 7635B
Blue Sea Systems Inc. p 360.738.8230
425 Sequoia Drive f 360.734.4195
Bellingham, WA 98226 USA conductor@bluesea.com
www.bluesea.com
980016770 Rev.002
WARNING
CAUTION
Installation
GUARANTEE: Blue Sea Systems stands behind its products for as long
as you own them. Find detailed information at www.bluesea.com/about.
For customer service, call 800-222-7617.
Senses low battery voltage and automatically disconnects
devices to save power for starting or to preserve battery life
Status light in both m-LVD and Remote Control Switch provides visual warning of low
voltage state prior to disconnect
Alarm output available for audible warning of low voltage state
prior to disconnect (optional alarm required)
Remote Control Switch Functions:
Disconnect Voltage Adjustment - Sets desired disconnect voltage
Override - Temporarily delays circuit disconnect for 10 minutes
OFF - Temporarily disconnects circuits until voltage rises
Override or OFF - Silences alarm (optional alarm required)
Includes Remote Control Switch PN 7928
DC
AC
Before beginning electrical installation, disconnect all AC and DC power sources.
Do not service equipment that has been automatically disconnected by the m-LVD
withoutrstpermanentlyremovingpowerfromtheequipmentbyameansother
than the m-LVD.
WARNING
CAUTION
If you are not knowledgeable about electrical systems, consult an electrical professional.
Mount the m-LVD. Three mounting options are illustrated below:
1.00
"
(25.4mm)
SUGGESTED
MINIMUM SCREW
LENGTH
#10 SCREWS
WITH THREAD
APPROPRIATE
FOR MOUNTING
SURFACE
2-5/8" (66.7mm)
MOUNTING HOLE
DIAMETER
5/16" (7.9mm)
MAXIMUM PANEL
THICKNESS
2-5/16" (58.7mm)
MOUNTING HOLE
DIAMETER
1.00
" (25.4mm)
SUGGESTED SCREW
LENGTH FOR 1/8"
PANEL THICKNESS
#10 HEX NUTS
3/8" WIDTH
#10 MACHINE
SCREWS
2.25 (57.2mm)
SUGGESTED MINIMUM
SCREW LENGTH
#10 SCREWS
WITH THREAD
APPROPRIATE
FOR MOUNTING
SURFACE
Rear Panel Mount
Front Panel Mount
Surface Mount
Front Panel Mount (Rear View)
m -LVD
LOW VOLTAGE DISCONNECT
Scan for
additional
product
information
1.45"
(36.83mm)
0.83"
(21.08mm)
Remote Control Switch
Mounting Hole Dimensions
Intermittent Rating: 5 min. 115A
Continuous Rating 65A
Nominal Voltage 12V DC
Cable Size (to meet current ratings) 6 AWG (16mm²)
Terminal Stud Size 1/4"-20 (M6)
Disconnect Voltage 11.3V12.1V Adjustable
Factory Default Disconnect Voltage 12.1V
Alarm Time Before Disconnect 5 minutes
Reconnect Voltage 13V DC
Remote Control Switch Type: SPDT, Action: (ON)-OFF-(ON)
( ) = momentary
Maximum Alarm Current 250mA
Maximum External LED Current 14mA
Regulatory
ISO 8846, Meets SAE J1171 external ignition protection requirements
Specications
Installation (continued)
Remove rear insulating cover as illustrated.

Summary of content (2 pages)