User Manual
DC LABEL BACKLIGHT AND CIRCUIT STATUS SYSTEM
CIRCUIT BREAKER MODULES
The label backlighting and circuit status indicator is pre-wired for
12 Volts DC:
1.Connect+12Voltstothe+12VDCquick-connectterminal(piggybacklug
on panels with jumper wires) on the LED circuit board.
2.ConnectthenegativeofthebatterysystemtotheNEGquick-connect
terminal (piggy back lug on panels with jumper wires) on the LED
circuit board.
To convert the label backlighting and circuit status indication to
24 Volts DC:
1.Replacethe12VoltDCLEDharnesswitha12to24VoltDCConversion
Kit(PN4113,notincludedwiththepanel).
Note:360panelswithmorethanonemodulehavebacklightjumper
wires connecting modules. These jumper wires must be moved when
connectingto24VoltsDC.
2.Movejumperwiresfromthe+12VDCquick-connectterminaltothe
+24VDCquick-connectterminalontheLEDcircuitboard.
3.Connect+24Voltstothe+24VDCquick-connectterminal(piggybacklug
on panels with jumper wires) on the LED circuit board.
4.ConnectthenegativeofthebatterysystemtotheNEGquick-connect
terminal (piggy back lug on panels with jumper wires) on the LED
circuit board.
6
Formoreinformationgotowww.bluesea.com
+12V DC
+24V DC
NEG.
12V DC LED harness
12V DC quick connect terminal
12V DC LED circuit board
24V DC quick connect terminal
NEGATIVE quick connect terminal