INSTALLATION MANUAL SIMRAD CS65 Chart System 20221917D Sw.2.
Simrad CS65 Chart system About this document Rev A Date Written by Checked by Approved by 300604 First issue. 241105 B C New back-up/restore procedure. New software release (1.2.xx) with minor changes in System Configuration dialog. COP20 (Option) included. 200106 CD-RW replaced with DVD. 070906 D New software release (2.1.xx.) implementing the IMO S-52 requirements (C-MAP SDK 3.6). Minor changes to MMI. © 2004-2006 Simrad AS. All rights reserved.
INSTALLATION MANUAL Content 1 2 INTRODUCTION ................................................................1 1.1 General .............................................................................1 1.2 Unpacking and handling ......................................................1 1.3 System components............................................................2 INSTALLATION..................................................................3 2.1 Location of the units ............................
Simrad CS65 Chart system 4 5 BACK-UP AND RESTORE PROCEDURES ............................23 4.1 General ........................................................................... 23 4.2 Making a back-up ............................................................. 23 4.3 Restoring the software ...................................................... 24 4.4 Re-installing/updating the CS software ................................ 25 TECHNICAL SPECIFICATIONS .........................................
INTRODUCTION 1 INTRODUCTION 1.1 General This manual provides detailed information required to successfully install and configure the CS65 system. The manual must be used in conjunction with the instructions and drawings designed for the specific vessel, and should remain with the vessel on completion of the installation to serve as an additional reference during maintenance of the system. 1.2 Unpacking and handling Care should be taken when unpacking and handling the equipment.
Simrad CS65 Chart system 1.3 System components A standard CS65 system includes the following units: - MC30 Marine computer - FB200 MC 24V DC Filterbox - Cherry keyboard - Logitech TrackMan® wheel - Speaker - Color monitor (may be supplied by others) The basic system may be expanded with a COP20 Operator panel, a COP10 remote operator panel, and with a printer.
INSTALLATION 2 INSTALLATION 2.1 Location of the units The units included in the CS65 system should be mounted with special regard to the units’ environmental protection, temperature range and cable length. The CS65 units are designed to operate within the temperature range of 0°C to +55°C. However, it is recommended that adequate ventilation/air-conditioning is provided in order to keep the ambient operating temperature at +20°C.
Simrad CS65 Chart system Speaker A mounting bracket used for securing the speaker to the panel is included in the delivery. The bracket is fastened to the speaker by using the 3 screws on the back of the speaker as shown on the figure. Refer dimensional drawing, page 38. Keyboard and TrackMan® wheel No installation devices are included for these units. Monitor Refer to separate documentation delivered with the monitor for installation procedures.
INSTALLATION COP10 Remote Operator panel (Option) COP10 is designed to be mounted in the helmsman chair’s armrest. 2.3 1 Cut the necessary holes in the armrest where COP10 is to be fitted. Refer COP10 dimensional drawing on page 40, and the cut-out template on page 43. 2 Secure the unit to the panel with the nut as shown on the figure. Grounding the units MC30 and FB200 should have a proper ground connection from the units’ ground terminal.
Simrad CS65 Chart system 2.4 Power connection MC30 is to be supplied with 24V DC. The power should be connected to the MC30 via the FB200 Filter box. Do not connect 24V without using this filter box. Doing so may course electromagnetic interference! 1 Note! Remove the cover on the FB200, and connect the cable from 24V DC supply according to the labeling on the terminals as shown on the figure below. This cable is not supplied with the equipment! It should have a cross section of at least 2.
INSTALLATION 2.5 Cable connections Refer to CS65 Cabling diagram, page 42. Cable layout The figure below shows the MC30 connector layout. rp_ cfobtfob `lj=O ` l j P ` l j Q The table lists number and type of ports that are available: 2 PS2 ports. 2 Firewire ports. 4 USB ports. 1 Ethernet port. The ethernet cable should be removed when not in use. If the cable is connected, this may slow down the computer capacity. 4 Line in/out connectors. 1 Monitor connector.
Simrad CS65 Chart system Printer port. 24V DC power input. Connecting external equipment 2 optical isolated NMEA converters are included in the CS65 system. These must be used for connecting external equipment to COM1 and COM2 on the MC30. Connect the 9-pins plug to the selected communication port on MC30, and connect the cable to external equipment according to the manufacturer’s specification and according to the table below.
INSTALLATION Connecting the optional operator panels If a COP20 is to replace the Cherry keyboard and the TrackMan Wheel, the keyboard and mouse cable on COP20 are connected to the computer’s PS2 ports. COP20s signal cable is connected to an external power for keyboard illumination as shown on the figure below. If an optional COP10 is to be used in the chart system, this unit is connected between the keyboard (or the keyboard plug on COP20) and the PS2 port.
Simrad CS65 Chart system THIS PAGE INTENTIONALLY LEFT BLANK 10 20221917 / D
SYSTEM CONFIGURATION 3 SYSTEM CONFIGURATION 3.1 The System configuration dialog All configuration of the CS system is done from the System Configuration dialog. This dialog is the entrance to all settings that have to be done when configuring the system. Note The following pages list the settings as they appear in the dialogs. All these settings have to be performed before the CS system is ready for operation.
Simrad CS65 Chart system Note Data entered in the System Configuration dialog are not taken into account until it is confirmed by clicking the OK or APPLY buttons: •OK: changes are applied, and the dialog box is removed from the display •APPLY: changes are applied, and the dialog box remains displayed. The different tabs in the System Configuration dialog are described in the following pages. Ref page: Used to configure external devices. 13 Used for configuring the output format.
SYSTEM CONFIGURATION Adding new device New devices are configured by pressing the New button when the Inputs tab in the System Configuration dialog is active. The Input Config dialog is displayed. Note Which data that is available in the Input Config dialog depends on which device type that is selected. The Input Config dialog has the following fields: Device Name Name for the input device. The device name is limited to 8 characters.
Simrad CS65 Chart system Navigator Datum Valid flag Antenna position offset from ref. point Specification for differential GPS. Must be entered if Navigator or AIS is selected as device type. Values for antenna offset for Navigator and AIS devices. All sensors refer to the vessel’s reference point. This point is defined in Ship settings, page 22. If no reference is defined, the vessel’s center of gravity will be used as reference point.
SYSTEM CONFIGURATION Advanced input settings By pressing the Advanced button when the Inputs tab in the System Configuration dialog is active, the Advanced Input Settings dialog is displayed. This dialog is used for advanced settings for ARPA, log, gyro, position reference sentences and Ethernet connection. All tabs in this dialog have text specifying the different data fields as shown in the “arp” tab shown below.
Simrad CS65 Chart system Deleting an input device A defined input device is deleted by activating the device in the Inputs tab, and then pressing the Delete button. To avoid unintended removal of a device, the selection has to be confirmed by pressing the OK button. Monitoring a serial line The Monitor Serial Line button in the Input tab in the System Configuration dialog makes it possible to monitor each serial line individually.
SYSTEM CONFIGURATION The buttons in the dialog are used as follows: Close: Closes the dialog and returns the display to the Inputs tab in the System Configuration dialog. Freeze: Stops the text from scrolling. Clear: Clears the text field in the dialog. Hex/ASCII: Log Activate: Toggles the log data between hexadecimal and ASCII characters. Saves the monitored log data to a file. A new dialog for selecting file name and location will be displayed.
Simrad CS65 Chart system 3.4 Checksum NMEA data sent to the CS system may contain a checksum. When the CS system receives data with checksum included, it will automatically calculate the checksum and compare this sum with the checksum transmitted by the device. When the calculated and the received checksum not are identical, the settings in the Checksum tab in the System Configuration dialog will decide whether the CS system will use or reject these data.
SYSTEM CONFIGURATION 3.5 Auxiliary settings Screen decimals Number of decimals displayed for the position reference in the Position Window. In the example below, 4 decimals are selected. NMEA decimals Number of decimals used in the data output sentences. Stepper Gyro Not used. Voice Alarm Toggles voice alarm function ON/OFF. Start Route Replication Enables route replication between ECDIS and Backup machine in PLECDIS configurations.
Simrad CS65 Chart system 3.6 Miscellaneous settings Time Zone Time zone according to UTC. The system will read the UTC time from the GPS and update it to local time. Screen size Used for setting correct diagonal screen size. When pressing the Start RULER button, a new dialog for entering screen size is opened. Press the Measure the Screen button to open a new dialog used for measuring a selected area directly on the monitor.
SYSTEM CONFIGURATION Caution The Screen size MUST be set correctly to display the correct chart scale and to place targets correctly in the chart. If the screen size is wrong AIS target in the outer end of the screen area will be positioned incorrectly. After Screen size has been adjusted the chart system must be restarted to synchronize the screen settings. By pressing this button, the built in alarm system will issue an alarm for 5 seconds.
Simrad CS65 Chart system 3.7 Ship settings Ship name Type of ship Type of cargo/operation MMSI Parameters used when transmitting AIS information. These fields should be entered correctly to ensure that correct information will be used in the AIS system. IMO Call Signal Measurements Parameters used by the CS system to draw a ship symbol in true size. Used when the actual ship is larges that the minimum ship symbol. Note that the reference offset points are calculated from the vessel’s center point.
BACK-UP AND RESTORE PROCEDURES 4 BACK-UP AND RESTORE PROCEDURES 4.1 General When the CS system is delivered from Simrad, the software for both operating system and chart system are pre-installed from factory. WARNING No additional software should be installed on the MC30 computer. Doing so may cause malfunction on the CS system! When the CS system is installed and configured, it is strongly recommended to make a back-up of the complete installation.
Simrad CS65 Chart system Press 1, 3 or 5 to start the selected backup procedure. A running progress bar indicates that the back-up procedure is running. 4.3 4 Follow the instructions on the display, and eventually insert a new CD/DVD if required. 5 Press any key to return to the main menu when the backup is completed. 6 Remove the CD/DVD and restart the computer. 7 Label the CDs/DVDs and make sure that they are kept in a safe location.
BACK-UP AND RESTORE PROCEDURES 4.4 4 Press 2, 4 or 6 to start the selected restore procedure. A running progress bar indicates that the procedure is running. 5 Follow the instructions on the display, and eventually insert a new CD/DVD if required. 6 Press any key to return to the main menu when the restore is completed. 7 Remove the CD/DVD and restart the computer.
Simrad CS65 Chart system 26 3 Press the Finish button, and restart the computer. The operating system will now be started, automatically followed by the CS chart system. 4 Configure the software as described in SYSTEM CONFIGURATION, page 11 onwards.
TECHNICAL SPECIFICATIONS 5 TECHNICAL SPECIFICATIONS 5.1 Cabling Cable length for standard and optional units in the CS65 system is shown on the figure below. 2 1 10 3 8 9 7 5 4 6 20221917 / D CABLE NO. CABLE LENGTH DESCRIPTION 1 1.4 m Part of FB200 Filterbox 2 1.0 m Part of speaker 3 - 4 1.6 m Part of Cherry keyboard 5 1.8 m Part of Logitech TrackMan wheel 6 5.0 m Part of COP10 (OPTION) 7 5.0 m (System) 8 1.5 m (Keyboard) 9 1.
Simrad CS65 Chart system 5.2 MC30 computer unit Height: ..................................188 mm Width: ...................................320 mm Depth: ...................................258 mm Net weight............................. 5,9 Kg Color: .................................... Black Environmental Protection: .... IP22 Temperature range: Operating:....................0 to +55 °C (+32 to +131 °F) Storage:........................–15 to +85 °C (+5 to +185 °F) Dimensional drawing:...........
TECHNICAL SPECIFICATIONS 5.4 Speaker Height: ......................................... 163 mm Width: .......................................... 68 mm Depth: .......................................... 95 mm Color: ........................................... Grey Effect (PMPO): ............................ 80 watt max Frequency range: ......................... 20Hz – 80 kHz Environmental Protection: ........... IP22 Dimensional drawing (bracket): .. page 38 5.5 FB200 Filterbox Height: ....................
Simrad CS65 Chart system COP20 Operator panel (Option) Height: ............................................................................. 220 mm Width: .............................................................................. 440 mm Depth: .................................................... 135 mm incl. cable bend Net weight...........................................................................3.8 Kg Color: ...................................................................................
TECHNICAL SPECIFICATIONS 5.7 IP protection Each part of a Simrad CS65 system has got a two digits IP protection code. The IP rating is a method to classify the degree of protection against solid objects, water ingress and impact afforded by electrical equipment and enclosures. The system is recognized in most European countries and USA and is set out in a number of British and European standards.
Simrad CS65 Chart system THIS PAGE INTENTIONALLY LEFT BLANK 32 20221917 / D
DRAWINGS 6 DRAWINGS The following drawings are enclosed: Name Drw.no Rev. N3-605560 A Cherry keyboard, Dimensional drawing N4-081309 - Mounting bracket for speaker, Dimensional drawing D3-605554 A FB200, Dimensional drawing D3-604913 A COP10 (OPTION). Dimensional drawing N3-605303 A COP20 (OPTION).
Simrad CS65 Chart system 6.
DRAWINGS Side view 20221917 / D 35
Simrad CS65 Chart system Top view 36 20221917 / D
DRAWINGS 6.
Simrad CS65 Chart system 6.3 Mounting bracket for speaker 38 [1.50] SPEAKER FRONT 80 [3.15] 90 [3.
DRAWINGS 6.
Simrad CS65 Chart system 6.
DRAWINGS 6.
42 GND TX- TX+ RX- RX+ GND OPTIONAL CONNECTORS FOR EXTERNAL EQUIPMENT + GND - GND GND TV OUT `Ü~êí=ëóëíÉã `~ÄäáåÖ=Çá~Öê~ã `pSR N N 20221917 / D klot^v kP J SMRRSN _ bdboprka páãê~Ç=bÖÉêëìåÇ=^p BROWN + + 24V DC POWER INPUT PARALLEL NOT USED EXTERNAL POWER FOR KEYBOARD ILLUMINATION GND USB 5m +12V USB COP20 (OPTION) MOUSE GREEN USB MONITOR SPEAKER 1.7 m 1.5 m 1.8 m KEYBOARD YELLOW MONITOR USB AUDIO OUT ETHERNET FIREWIRE FIREWIRE PS2 1.
DRAWINGS 6.
Simrad CS65 Chart system 44 20221917 / D
DRAWINGS 6.