Appliance Trim Kit User Manual
Volume 9: Managing the Blue Coat SG Appliance
56
Related CLI Syntax to Define Packet Capturing Settings
SGOS# pcap filter parameters
SGOS# pcap start [subcommands]
To start, stop, and download packet captures through a browser:
1. Start your Web browser.
2. Enter the URL:
https://appliance_IP_address:8082/PCAP/Statistics and log
on to the appliance as needed.
The Packet Capture Web page opens.
3. Select the desired action:
Start packet capture, Stop packet capture, Download packet
capture file
.
You can also use the following URLs to configure these individually:
❐ To start packet capturing, use this URL:
https://SG_IP_address:8082/PCAP/start
❐ To stop packet capturing, use this URL:
https://SG_IP_address:8082/PCAP/stop
❐ To download packet capturing data, use this URL:
https://SG_IP_address:8082/PCAP/bluecoat.cap
Viewing Current Packet Capture Data
Use the following procedures to display current capture information from the SG
appliance.