System Management: CPU temperature monitoring, system temperature monitoring, CPU fan speed
monitoring and voltage monitoring of Vcore, +3.3V, +5V, +12V, -12V and Vbat
are all available to the application for monitoring and reporting.
Power Requirements: Auto-ranging 115 - 230V / 4 – 2A / 60 - 50Hz, with IEC320 power inlet.
Environmental Conditions: Operating temperature range +5 ºC to +40 ºC in free air.
Storage temperature range -20 ºC to +70 ºC
Relative Humidity 10-85% non-condensing.
Shock and vibration compatible with light industrial usage.
Construction: Painted zinc-plated sheet steel, welded and riveted construction.
Dimensions: 425 x 245 x 62 mm, excluding the earth (ground) stud and the mounting
brackets.
Note that an additional 130 mm will be required in front of the CD/DVD for the
tray to eject, and at least 60 mm to allow easy access to the cable connectors.
Air vents must not be obstructed. A minimum gap of 25 mm between vents and
any adjacent items is recommended.