Specifications

10
TROUBLESHOOTING SUGGESTIONS
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker tripped
Check power supply cord Check / reset
circuit breaker
Thermostat set too low Set for desired temperature
Hi-Limit thermostat tripped Allow to cool, Reset hi-limit
Damaged internal component or wiring
Examine wiring & connectors, thermostat
and heating element, Repair/replace as
needed
Trips hi-limit safety at start-up
No water or too little water added at start-up
Be sure to add sufcient water prior to
energizing
Coffee level low (pour-over)
Not enough water poured in Increase water amount
Too much coffee grounds Adjust amount of grounds
Coffee level too high or low
(automatic) Timer out of adjustment Adjust timer
Brew chamber overows
Too many lter papers or wrong lter paper
Use one (1) genuine Bloomeld lter per
brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Too much coffee or too ne a grind Adjust coffee amount and grind
Sprays water from brew head
incorrectly
Spray gasket missing or improperly installed
Check/reinstall gasket on INSIDE of brew
head
Spray disk plugged Clean spray disk
No brew (automatic)
Water supply OFF Turn water supply ON
Water line strainer plugged Clean strainer
Water lter (if used) plugged Replace lter element
Damaged BREW switch Replace switch
Damaged internal component or wiring
Examine wiring & connectors, brew timer
and solenoid, Repair/replace as needed
No ow from hot water faucet
Faucet valve turned OFF Turn faucet valve ON
Faucet plugged Disassemble faucet, clean
Poor coffee quality
Water not hot enough Adjust water temp 195-205ºF
Also:
Keep brewer, and decanters clean.
Install a taste and odor lter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast.
Use proper grind and amount of coffee per brew.
605 p/n 2M-70988 8752 Owmers Manual
605 p/n 2M-70988 8752 Owmers Manual