Specifications
SERVICING INSTRUCTIONS
ACCESS PANELS
Each warmer plate has a center stud which screws into a bracket.  
Warmer plates on Canadian brewers are secured with a nut. 
Remove button plug on bottom of brewer to access nut on main 
warmer. Remove top panel to access nuts on top warmers.  
Remove warmer plates by turning counter-clockwise.
Solenoid door is held by two screws and a retaining lip.
IN-LINE BREWERS:
Top panel is held by two screws at the rear and a retaining lip at 
the front. Disconnect wires from the upper warmers.
Top front panel is held by two screws at the bottom and a  
retaining lip at the top.
Bottom front panel is held by two clips under the warmer plate.
CAUTION: 
SHOCK HAZARD
Opening access panels or 
removing warmer plates on this 
brew may expose uninsulated 
electrical components.
Disconnect brewer from 
electrical power before  
removing any panel or warmer 
plate.
Fig. 9 Access Panels
11
IL1621a
SOLENOID
DOOR
601 p/n 2M-75815 9003, 9010, 9012, 9016 Decanter Coffee Brewer