Owner`s manual
BREW WATER VOLUME ADJUSTMENT
(Ratio Change)
1.
Follow steps 1 through 4 in Timer Adjustment
Procedure.
2.
Turn the handle of the needle valve clockwise
IN (facing the valve stem and handle) to in-
crease the ratio. This causes more water to be
diverted to the dilute flow, and less to the brew.
A counter-clockwise OUT rotation will do the
opposite.
3.
Adjustments must be made in 1/4 turn incre-
ments to avoid drastic changes. One (1) full
turn in either direction is the maximum ad-
vised. Average factory setting is two full
turns counter-clockwise from a fully closed
position.
NEEDLE VALVE
FOR BREW RATIO
-
CHANGE
SOLENOID
VALVE
-
4.
Water flow from spray disc and dilute spout
should be measured separately to determine
that the desired ratio has been achieved.
NOTE: If flow from spray disc is very weak and
slow in starting, the ratio adjustment made is
starving the brew water flow.
If, however, water flows from the vent tube,
located next to the spray disc assembly, then
the ratio of water for brewing is too great. It is
advisable that the spray disc and vent tube be
viewed after an adjustment has been made.
5.
After desired adjustments have been made, a
complete brew should be made to insure
quality of finished product.
TOP VIEW WITH
COVER REMOVED
FRONT OF BREWER
Page 5
-
THERMOSTAT
HIGH LIMIT
-
CONTROL
ADJUSTMENT