industries HEATED DISPENSER HD8799 2-Gallon HD8802 5-Gallon

INSTALLATION 
4 
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION 
REFER TO EXPLODED VIEWS PAGE 9 FOR COMPONENT 
NAMES/NUMBERS 
Unpack the unit. Inspect all components for completeness and 
condition. Ensure that all packing materials have been removed 
from the unit. 
LEVELING THE UNIT 
Verify that a slip-resistant foot is installed at each corner of the 
dispenser. 
Set the warmer in its operating location. Be sure all four feet 
touch the counter to prevent tipping. 
ELECTRICIAN’S INSTALLATION INSTRUCTIONS 
REFER TO ELECTRICAL SPECIFICATIONS - Page 1 
Check the nameplate to determine correct electrical service 
required for the warmer. 
Models HD8799 and HD8802 dispensers are equipped with a 
cord and plug. They requires a 115 - 125 volt circuit (50/60 Hz, 
2 wire plus ground, with NEMA 5-15R receptacle). 
IMPORTANT: The ground prong of the plug is part of a system 
designed to protect you from electrical shock in the event of 
internal damage. Never cut off the ground prong nor twist a 
blade to fit an existing receptacle. Contact a licensed electrician 
to install the proper circuit and receptacle. 
CAUTION: Equipment 
Electrical Damage 
DO NOT plug in or energize this 
appliance until all Installation 
Instructions are read and  
followed. Damage to the 
Brewer will occur if these 
instructions are not followed. 
CAUTION: Unstable 
Equipment Hazard 
It is very important for safety 
and for proper operation that the 
warmer is level and stable when 
standing in its final operating 
position. Provided non-skid feet 
must be installed at each corner 
of the unit.  Do not install this 
appliance if the feet are missing 
or damaged. 
WARNING ELECTRIC 
SHOCK HAZARD: 
Warmer must be properly 
grounded to prevent possible 
shock hazard. Electrical shock 
will cause death or serious  
injury. 
IMPORTANT: 
Supply power must match 
nameplate for voltage and 
phase. Connecting to the 
wrong voltage will damage the 
warmer or result in decreased 
performance. Such damage is 
not covered by warranty. 
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN