Specifications

17
TROUBLESHOOTING SUGGESTIONS
DESCRIPTION OF
PROBLEM
POSSIBLE CAUSE SUGGESTED REMEDY
No lights or heat
Unit not plugged in or circuit breaker tripped Restore electric power
Power switch OFF Turn power switch ON
No heat Hi-limit safety tripped
Allow brewer to cool, verify water level, reset
hi-limit
Brewer overows
Water level probe corroded Clean water level probe
Poor ground connection Verify ground connection
Dirt in inlet valve or valve damaged Replace inlet valve
Brew valve damaged Replace brew valve
Brew chamber
overows
Too many paper lters or wrong lter used.
Use one genuine Bloomeld paper lter per
brew
Chamber discharge hole plugged Clean brew chamber
Improper programming Correct programming
Heats slow
Connected to wrong voltage Verify supply voltage
Scale build-up on heating elements De-lime hot water tank
Damaged heating element Replace element
Slow to ll
Insufcient water pressure
Brewer must be operated on a dedicated water
line. Other equipment on line may be robbing
water volume.
Plugged water line strainer Clean strainer
Satellite does not heat
Not properly seated Seat satellite in receptacle
Fuse blown Correct problem, replace fuse
Damaged satellite receptacle or wiring Determine/repair damage to satellite
Damaged brewer receptacle Repair/replace receptacle
Satellite shorts out Wet insulation
Disassemble satellite, allow to dry completely
before reassembly
Poor coffee quality
Improper programming Correct programming
Also:
Keep brewer and servers clean.
Install a taste and odor lter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind and amount of coffee per brew.