Operating instructions

OPERATION (continued)
5
Changing time can also be
done in the regular
programming mode.
Consult the Programming
section in this manual to set
the After Hours mode.
Consult the Programming
secti on in thi s manual to
change the Countdown Quality
Timer™ feature:
To set the Keypadlock™ refer
to the Programming section in
this manual, Machine Settings
Menu.
Refer to page 2 for key designations
Changing Day and Time:
To change time, (Brewer in on mode.) Press the 3rd and 4th key at
the same time to access the time change mode. In the time change
mode the screen will read 'Day:" foll owed by the current day
setting. Use the 6th key to advance the day, or the 5th key to re-
verse. When day has been properly set press the 3rd key. The
screen will now read "Time:" with the set time on the screen, the
hour and am or pm flashing. Use the 5th key to go back or the 6th
key to advance the hour, making sure that the am or pm is correct.
When the hour and am/pm is correctly set press the 3rd key,
and the screen will read "Time:" with the set time on the screen,
minutes flashing. As previously, use the 5th or 6th keys to adjust
the minutes, and press the 3rd key when complete. )
After Hour:
The factory programming has the After Hours™ mode turned ON.
The After Hours™ can be program med to co me on from 1 to 6
hours after the last brew. When the SS2 goes into the After
Hours mode, the water in the tank will be allowed to drop from
the normal brewing temperature and will reheat less frequently.
This feature saves energy and extends component life. When the
BREW switch is pressed the SS2 automatically reverts back to
normal operation, heating the water to the Precise Temperature for
Brewing™ (PTB™), before starting the brew. The Brew light will
flash until the correct water temperature is reached.
Countdown Quality Timer™:
The SS2 factory programming has the Countdown Quality Timer
turned ON for satellite brewing.
Keypadlock™:
This feature is OFF in the standard factory settings. If the
Keypadlock™ feature i s activated, there will be no response by the
brewer when the keys are depressed (except for the beep after a
key is depressed).
To temporarily "unlock" the keypad, press and hold the CANCEL
key for 6 seconds. A beep will be heard indicati ng the keypad is
now "unlocked", - a brew can be initiated, etc. The keypad will
remain unlocked until the brew is completed, then automatically
return to Keypadlock™ mode. If a brew is not initiated 60 seconds
after "unlocking", the system will time out and return to the "locked"
position.
Pulse or Pre-infusion Volume System:
To set these features, refer to the Programming section in this
manual, Brew Settings Menu. This feature maybe set for any
volume key.
Bypass Valve System:
Refer to programming section under brew settings menu item. This
feature may be set for any volume key.
675 p/ n 74346 SS-2 Programming Manual