Specifications

5
INSTALLATION INSTRUCTIONS
INSTALL LEGS
The brewer is provided with adjustable legs. Be sure all four legs
are securely screwed into the base of the brewer.
LEVEL THE UNIT
The adjustable legs allow the brewer to be leveled. Set the brewer
in its ultimate operating location and check for level with a spirit
level Adjust the brewer for level from front-to-rear, and from side-
to-side. Be sure all four feet rest rmly on the counter.
PLUMBER’S INSTALLATION INSTRUCTIONS
IMPORTANT:
This equipment must be installed in accordance with the Basic
Plumbing Code of the Building Ofcials and Code Administrators
International (BOCA), and the Food Service Sanitation Manual
of the Food and Drug Administration (FDA). Also, this equipment
installation must comply with all local plumbing codes and
ordinances.
IMPORTANT:
Brewer must be installed on a water line with a full-ow pressure
between 20 psi and 90 psi.
NOTE: If water pressure varies greatly, or exceeds 90 psi at any
time, a water pressure regulator must be installed. Plumbing
installer must supply the regulator.
Brewer must be connected to a potable water supply. Bloomeld
recommends not less than 1/4” copper tubing for installations of
12’ or less, and not less than 3/8” copper tubing for installations
exceeding 12’. Brewer must be connected to a COLD water line.
NOTE: DO NOT use a saddle tap for this water line connection.
A shut-off valve must be installed between the main water supply
and the brewer. Plumbing installer must supply the shut-off valve.
A 1/4-turn ball valve is recommended.
Brewer INLET FITTING is 1/4” Male Flare.
Fig. 3 Water Line Installation
Flush the water line before connecting to the brewer.
CAUTION:
Hazard from
Unstable Equipment
Rubber feet must be installed
on each leg of the brewer. Legs
must be adjusted so that all four
feet rest rmly on the counter.
Failure to properly install the
feet can result in movement of
the brewer, which can cause
personal injury and/or damage
to the brewer.
Fig. 2 Adjustable Legs
IMPORTANT:
In some areas, local codes
require a backow preventer
(check valve) to be installed
on the inlet water line. If a
backow preventer is used, you
must install a water hammer
arrester in the incoming line,
between the backow preventer
and the brewer inlet, as far
away from the brewer as space
will allow. This will relieve the
excessive back pressures that
can cause faucet leaks and
solenoid malfunctions.
NOTE:
While new-style brewers
incorporate an internal strainer
in the inlet solenoid, the
provided “Y” strainer should be
installed in the incoming water
line for ease of servicing.
IL1845