Specifications

13
CAUTION:
SHOCK HAZARD
Live electrical circuits are
exposed during this procedure.
Use care to avoid uninsulated
electrical connectors.
Adjustments to be performed by
qualied technician only.
NOTE:
1/8 turn = approx 10ºF (5.5ºC)
TEMPERATURE ADJUSTMENT
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
FREQUENCY: As required to adjust delivered volume
TOOLS: Phillips head screwdriver
1. Press HEATER ON/OFF switch to OFF. Turn POWER
switch on back of brewer OFF.
2. Remove TOP PANEL. Operating controls are accessible
through the top panel only.
3. Remove vent tube from the tank cover and insert a
thermometer of known accuracy.
4. Locate the CONTROL THERMOSTAT on the right side of the
top housing
Turn CLOCKWISE to increase temperature
Turn COUNTER-CLOCKWISE to decrease temperature
1/8 turn is equal to approximately 10ºF change.
5. Turn POWER switch ON. Press TANK HEATER switch to
ON.
6. Allow the brewer to come up to brewing temperature. When
READY-TO -BREW light comes on, check temperature on
thermometer. Readjust thermostat as necessary.
7. When desired temperature is achieved, remove thermometer,
replace vent tube and reinstall top panel.
Procedure is complete
SERVICING INSTRUCTIONS (continued)
663 p/n 2M-76061 Owners Manual Satellite Coffee Brewer
IL1601
BOILING
POINT OF
WATER
ELEVATION (feet above sea level)
210
205
200
195
190
MAXIMUM
TEMPERATURE
SETTING
IDEAL
BREWING
TEMPERATURE
TEMP ( F)
IL1602
ELEVATION (meters above sea level)
100
0
150
300
450
600
750
900
1,050
1,200
1,500
1,650
1,800
1,950
1,350
97
94
91
88
BOILING
POINT OF
WATER
MAXIMUM
TEMPERATURE
SETTING
IDEAL
BREWING
TEMPERATURE
TEMP ( C)